AQW614
4. Reverse (ON) time vs. ambient temperature
characteristics
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
1.2
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
1.0
0.8
0.6
0.4
0.2
0 –40 –20 0 20 40 60 8085
Ambient temperature, °C
7. LED dropout voltage vs. ambient tempera-
ture characteristics
LED current: 5 to 50 mA
1.5
1.4
1.3
1.2
50mA
30mA
1.1
20mA
10mA
5mA
1.0
0 –40 –20 0 20 40 60 8085
Ambient temperature, °C
10. LED forward current vs. operate (OFF) time
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
3.0
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
2.5
2.0
1.5
1.0
0.5
0
10 20 30 40 50 60
LED forward current, mA
5. LED operate (OFF) current vs. ambient tem-
perature characteristics
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
6
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
5
4
3
2
1
0 –40 –20 0 20 40 60 8085
Ambient temperature, °C
8. Voltage vs. current characteristics of output
at MOS portion
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
Between terminal
100
7 and 8
(N.C.)
80
60
40
20
–5 –4 –3 –2 –1
1
–20
–40
Between terminal
5 and 6 (N.O.)
2345
Voltage, V
–60
–80
–100
11. LED forward current vs. reverse (ON) time
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC); Continuous load current:
100 mA (DC); Ambient temperature: 25°C 77°F
0.6
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
0.5
0.4
0.3
0.2
0.1
0
10 20 30 40 50 60
LED forward current, mA
6. LED reverse (ON) current vs. ambient tem-
perature characteristics
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
6
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
5
4
3
2
1
0 –40 –20 0 20 40 60 8085
Ambient temperature, °C
9. Off state leakage current
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
10–3
10–6
Between terminal 7 and 8 (N.C.)
10–9
10–12
0
Between terminal 5 and 6 (N.O.)
20
40
60
80 100
Load voltage, V
12. Applied voltage vs. output capacitance
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
120
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
100
80
60
40
20
0
10 20 30 40 50 60