Saturation Irradiance for Maximum Sensitivity [12]
Parameter
Saturation
Irradiance
Symbol
Conditions
lP = 460 nm
Refer Note 9
lP = 542 nm
Refer Note 10
lP = 645 nm
Refer Note 11
lP = 645 nm
Refer Note 11
B
G
R
Clear
Minimum
Typical (Note 3)
0.27
0.22
0.16
0.16
Maximum
Units
mW/cm2
Notes:
 1.  The “Absolute Maximum Ratings” are those values beyond which damage to the device may occur. The device should not be operated at
these limits. The parametric values defined in the “Electrical Specifications” table are not guaranteed at the absolute maximum ratings. The
“Recommended Operating Conditions” table will define the conditions for actual device operation.
  2.  Unless otherwise specified, all voltages are referenced to ground.
  3.  Specified at room temperature (25°C) and VDDD = VDDA = 2.5 V.
  4.  Applies to all DI pins.
  5.  Applies to all DO pins. SDASLV go tri-state when output logic high. Minimum VOH depends on the pull-up resistor value.
  6.  Applies to all DO and DIO pins.
  7.  Refers to total device current consumption.
  8.  Output and bidirectional pins are not loaded.
9.  Test condition is blue light of peak wavelength (lP) 460 nm and spectral half width (l1/2) 25 nm.
10.  Test condition is green light of peak wavelength (lP) 542 nm and spectral half width (l1/2) 35 nm.
11.  Test condition is red light of peak wavelength (lP) 645 nm and spectral half width (l1/2) 20 nm.
12.  Saturation irradiance = (MSB)/(Irradiance responsivity).
1.0
0.8
0.6
0.4
0.2
0
400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700
WAVELENGTH (nm)
Figure 1. Typical spectral response when the gains for all the color channels are set at equal