Dimensions and Operating Characteristics
D4C
Switches
Standard Models
Models without LED indicators are shown in the illustrations and dimensions diagrams. Refer to page 11 for Models with LED Indicators.
The boxes in the model numbers are replaced with the rating and cable type. Refer to page 1 for the Model Number Structure.
Pin Plunger
D4C-@@01
PT
OP
54.2 max.
49 max.
40 max.
25±0.1
10 dia. stainless
steel plunger
Two,
5.1
+0.2
0
dia.
holes
Spot facing
16
10.2 dia. Depth: 6
4.5
7.5
8
Correct
setting
position
2.8
2 23
Roller Lever
D4C-@@20
D4C-@@20-P
17.5 dia. x 7 stainless
sintered roller
40 max.
25±0.1
50 max.
44±0.8
30.2±0.8
31.5±0.8
38R
16
VCTF cable,
0.75 mm2,
4 conductor
2
1.4
1.5
Finishing O.D.: 7.6
34
102.7 max.
7
2
11.4
7.5
8 M5 (length: 12)
Allen-head
bolt
23
65 max.
Roller Plunger
D4C-@@02
PT
OP
67 max.
51.5 max.
12 dia. x 4.4 stainless steel roller
40 max.
25±0.1
Two,
5.1
+0.2
0
dia.
16
holes
Spot facing
10.2 dia. Depth: 6
Correct
setting
position
2.8
7
7.5
8
2 23
VCTF cable,
0.75 mm2,
4 conductor
2
1.4
1.5
Finishing O.D.: 7.6
34
Crossroller Plunger
D4C-@@03
PT
OP
67 max.
51.5 max.
12 dia. x 4.4 stainless steel roller
40 max.
25±0.1
Two,
5.1
+0.2
0
dia.
holes
16
Spot facing
10.2 dia. Depth: 6
7
7.5
8
Correct
setting
position
2.8
2 23
VCTF cable,
0.75 mm2,
4 conductor
2
1.4
1.5
Finishing O.D.: 7.6
34
Two,
5.1
+0.2
0
dia.
holes
VCTF cable, *
0.75 mm2,
Spot facing
10.2 dia. Depth: 6
4 conductor
Finishing
2
1.4
1.5
O.D.: 7.6
34
* S-FLEX VCTF Cables are used for weatherresistant models.
Roller Lever (High-Sensitivity Model)
D4C-@@24
D4C-@@24-P
17.5 dia. x 7 stainless
sintered roller
50 max.
40 max.
25±0.1
44±0.8
30.2±0.8
102.7 max.
7
2
31.5±0.8
38R
16
11.4
7.5
8 M5 (length: 12)
Allen-head
bolt
23
65 max.
Two,
5.1
+0.2
0
dia.
holes
VCTF cable, *
0.75 mm2,
Spot facing
10.2 dia. Depth: 6
4 conductor
Finishing
2
1.4
1.5
O.D.: 7.6
34
* S-FLEX VCTF Cables are used for weatherresistant models.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating
characteristics
Model
Operating force OF
Release force RF
Pretravel
PT
Overtravel
OT
Movement Differential MD
max.
min.
max.
min.
max.
Operating Position OP
D4C-@@01
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
15.7±1 mm
D4C-@@02
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5±1 mm
D4C-@@03
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5±1 mm
D4C-@@20
D4C-@@20-P
5.69 N
1.47 N
25°
40°
3°
---
D4C-@@24
D4C-@@24-P
5.69 N
1.47 N
10°±3°
50°
3°
---