µPD168112
Example of Address Setting
LATCH
SCLK
SDATA
Address 0 Address 1
Address 4 Address 2
VD
Initialization
Address 0
Address 1
DC motor
Address 2
Address 4
Address 31 to 34 Address 2 Address 5 Address 2
Stepper motor
Address 2
Address 31 to 34
Constant-current driving
Address 2
Address 5
Be sure to perform initialization (addresses 0 and 1) immediately and after power application and RESET. Transmit
the data of only addresses 0 and 1 for the initialization operation. After the initialization operation, the system can be
controlled simply by inputting driving data (addresses 2 to 5). To execute initialization again, the RESET pin must be
mode high level.
To set a stepper motor, be sure to input the VD signal. If only the VD signal is input, the previous status is held and
the output does not change.