Test Circuit Example 8. (Conversion gain, –1 dB compression level)
µPC8002
82 pF
MIX OUT
2
LO IN
5
470 pF
50 Ω
MIX IN1
8
470 pF
See 6. TEST METHODS (1)
Spectrum
analyzer
SG
239.3 MHz
Test Circuit Example 9. (Third order intercept output level)
SG
250 MHz
82 pF
MIX OUT
2
LO IN
5
470 pF
50 Ω
MIX IN1
8
470 pF
See 6. TEST METHODS (2)
Spectrum
analyzer
SG
239.3 MHz
Test Circuit Example 10. (Local separation)
82 pF
MIX OUT
2
LO IN
5
470 pF
50 Ω
Spectrum
analyzer
SG
239.3 MHz