datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

XE1486 Просмотр технического описания (PDF) - Xecom

Номер в каталоге
Компоненты Описание
Список матч
XE1486 Datasheet PDF : 16 Pages
First Prev 11 12 13 14 15 16
XE1486 S-Registers (continued)
S28 Pulse Dialing Bit-Mapped Options: S28
S33 XOFF Character: S32 determines the character
stores the modem's pulse dialing format.
recognized as XOFF for in-band flow control.
Bit 0-2 Not Used
Range: 0 to 255
Bit 3-4 0 = Make/Break ratio 39%/61%; 10
Units ASCII Character
pulses per second (AT&P0)
Default 19 (DC3)
1 = Make/Break ratio 33%/67%; 10
pulses per second (AT&P1)
S36 LAPM Failure: S36 sets the modem reaction to
2 = Make/Break ratio 39%/61%; 20
error control negotiation failure.
pulses per second (AT&P2)
Bit 0-2 0 = Modem Disconnects
3 = Make/Break ratio 33%/67%; 20
1 = Establish Direct Connection
pulses per second (AT&P3)
3 = Establish normal Connection
Bit 5-7 Not Used
4 = Disconnect if MNP handshake
fails
S29 Hook Flash Timer: S29 sets the length of time
5 = Establish Direct Connection if
the modem closes its off-hook relay on receipt of
MNP handshake fails.
the "!" dial modifier to simulate a switch hook
7 = Establish Normal Connection if
flash.
MNP handshake fails.
Range: 0 to 255
Bit 3-7 Not Used
Units 10 milliseconds
Default 70
S38 Forced Disconnect Timer: S38 sets the delay
between receipt of the disconnect command and
S30 Disconnect on Inactivity Timer: S30 sets the
the opening of the switch hook. If S38 is set to
modem to disconnect after the given time period
255 the modem disconnects only after its buffers
with no data being sent or received. A 0 dis-
are empty.
ables the inactivity timer.
Range: 0 to 255
Range: 0 to 255
Units 1 Second
Units 10 Seconds
Default 20
Default 0
S39 Flow Control Bit-Mapped Options: S39
S31 General Bit-Mapped Options: S31 stores the
shows the status of the flow control options,
status of various AT commands.
AT&K.
Bit 0 0 = No single-line Connect messages
Bit 0-2 0 = Flow Control Disabled
(AT\V0)
3 = Hardware Flow Control, RTS/CTS
1 = Use single-line connect messages
4 = In-Band Flow Control XON/XOFF
(AT\V1)
5 = Transparent In-Band Flow Control
Bit 1 0 = No Automode detection (ATN0)
6 = Hardware & In-Band Flow Control
1 = Automode detection active (ATN1)
Bit 3-7 Not used
Bit 2-3 0 = Report host speed (ATW0)
1 = Report all parameters (ATW1)
2 = Report modem speed only (ATW2)
Bit 4-7 Not Used
S32 XON Character: S32 determines the character
to be sent as XON for in-band flow control.
Range: 0 to 255
Units ASCII Character
Default 11 (VT)
XECOM
(11)
XE1486

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]