AD7713
Parameter
Limit at TMIN, TMAX
(A, S Versions)
Units
Conditions/Comments
External-Clocking Mode
fSCLK
t20
t21
t22
t23
t246
t256
t26
t27
t28
t297
t30
t317
t32
t33
t34
t35
t36
fCLK IN/5
0
0
2 × tCLK IN
0
4 × tCLK IN
10
2 × tCLK IN + 20
2 × tCLK IN
2 × tCLK IN
tCLK IN + 10
10
tCLK IN + 10
10
5 × tCLK IN/2 + 50
0
0
4 × tCLK IN
2 × tCLK IN – SCLK High
30
MHz max
ns min
ns min
ns min
ns min
ns max
ns min
ns max
ns min
ns min
ns max
ns min
ns max
ns min
ns max
ns min
ns min
ns min
ns min
ns min
Serial Clock Input Frequency
DRDY to RFS Setup Time
DRDY to RFS Hold Time
A0 to RFS Setup Time
2
A0 to RFS Hold Time
Data Access Time (RFS Low to Data Valid)
SCLK Falling Edge to Data Valid Delay
SCLK High Pulse Width
SCLK Low Pulse Width
SCLK Falling Edge to DRDY High
SCLK to Data Valid Hold Time
RFS/TFS to SCLK Falling Edge Hold Time
RFS to Data Valid Hold Time
A0 to TFS Setup Time
A0 to TFS Hold Time
SCLK Falling Edge to TFS Hold Time
Data Valid to SCLK Setup Time
Data Valid to SCLK Hold Time
NOTES
1Guaranteed by design, not production tested. All input signals are specified with tr = tf = 5 ns (10% to 90% of 5 V) and timed from a voltage level of 1.6 V.
2See Figures 10 to 13.
3CLK IN duty cycle range is 45% to 55%. CLK IN must be supplied whenever the AD7713 is not in STANDBY mode. If no clock is present in this case, the
device can draw higher current than specified and possibly become uncalibrated.
4The AD7713 is production tested with fCLK IN at 2 MHz. It is guaranteed by characterization to operate at 400 kHz.
5Specified using 10% and 90% points on waveform of interest.
6These numbers are measured with the load circuit of Figure 1 and defined as the time required for the output to cross 0.8 V or 2.4 V.
7These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 1. The measured number
is then extrapolated back to remove effects of charging or discharging the 100 pF capacitor. This means that the times quoted in the timing characteristics are
the true bus relinquish times of the part and, as such, are independent of external bus loading capacitances.
1.6mA
TO OUTPUT
PIN
100pF
+2.1V
200µA
Figure 1. Load Circuit for Access Time and Bus Relinquish Time
REV. C
–5–