IDT723614 CMOS SYNCBIFIFOWITH BUS-MATCHING
AND BYTE SWAPPING 64 x 36 x 2
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATINGS OVER OPERATING FREE-AIR TEMPERATURE
RANGE (UNLESS OTHERWISE NOTED)(1)
Symbol
Rating
Commercial
Unit
VCC
Supply Voltage Range
–0.5 to 7
V
VI(2)
Input Voltage Range
–0.5 to VCC+0.5
V
VO(2)
Output Voltage Range
–0.5 to VCC+0.5
V
IIK
Input Clamp Current, (VI < 0 or VI > VCC)
±20
mA
IOK
Output Clamp Current, (VO < 0 or VO > VCC)
±50
mA
IOUT
Continuous Output Current, (VO = 0 to VCC)
±50
mA
ICC
Continuous Current Through VCC or GND
±500
mA
TSTG
Storage Temperature Range
–65 to 150
°C
NOTES:
1. Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only and functional operation of the device
at these or any other conditions beyond those indicated under "Recommended Operating Conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended
periods may affect device reliability.
2. The input and output voltage ratings may be exceeded provided the input and output current ratings are observed.
RECOMMENDED OPERATING
CONDITIONS
Symbol
VCC
VIH
VIL
IOH
IOL
TA
Parameter
Supply Voltage
HIGH Level Input Voltage
LOW-Level Input Voltage
HIGH-Level Output Current
LOW-Level Output Current
Operating Free-air Temperature
Min. Max. Unit
4.5 5.5 V
2 –V
– 0.8 V
– –4 mA
– 8 mA
0 70 °C
ELECTRICAL CHARACTERISTICS OVER RECOMMENDED OPERATING
FREE-AIR TEMPERATURE RANGE (UNLESS OTHERWISE NOTED)
Parameter
VOH
VCC = 4.5V,
IOH = –4 mA
VOL
VCC = 4.5 V,
IOL = 8 mA
II
VCC = 5.5 V,
VI = VCC or 0
IOZ
VCC = 5.5 V,
VO = VCC or 0
ICC(2)
VCC = 5.5 V,
IO = 0 mA,
CIN
VI = 0,
f = 1 MHz
COUT
VO = 0,
f = 1 MHZ
NOTES:
1 . All typical values are at VCC = 5 V, TA = 25°C.
2. For additional ICC information, see the following page.
Test Conditions
VI = VCC or GND
Min. Typ.(1)
2.4
4
8
Max. Unit
V
0.5
V
±50 µA
±50 µA
1
mA
pF
pF
6

Share Link: 