datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

IDT6178S20YB Просмотр технического описания (PDF) - Integrated Device Technology

Номер в каталоге
Компоненты Описание
Список матч
IDT6178S20YB
IDT
Integrated Device Technology IDT
IDT6178S20YB Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
IDT6178S
CMOS StaticRAM 16K (4K x 4-BIT) CACHE-TAG RAM
MILITARY AND COMMERCIAL TEMPERATURE RANGE
AC ELECTRICAL CHARACTERISTICS (VCC = 5.0V ± 10%, All Temperature Ranges)
6178S10(1)
6178S12
6178S15
Symbol
Parameter
Write Cycle
tWC
Write Cycle Time
tAW
Address Valid to End-of-Write
tAS
Address Set-up Time
tWP
Write Pulse Width
tWR
Write Recovery Time
tDW
Data Valid to End-of-Write
tDH
Data Hold from Write Time
tWHZ(2)
Write Enable to Output in High-Z
tOW(2)
Output Active from End-of-Write
Min. Max. Min. Max. Min. Max.
10
12
15
8
10
12
0
0
0
8
10
12
0
0
0
6
8
10
0
0
0
5
6
7
0
0
0
NOTES:
1. 0°C to +70°C temperature range only.
2. This parameter guaranteed with AC load (Figure 3) by device characterization, but is not production tested.
6178S20/25
Min. Max.
20
14
0
14
0
12
0
9
0
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
2953 tbl 12
TIMING WAVEFORM OF WRITE CYCLE(1,3)
tWC
ADDRESS
tAS
WE
tAW
tWP
tWHZ (4)
tWR
tOW (4)
DATAOUT
(2)
(2)
(4)
tDW
(4)
tDH
DATAIN
DATAIN VALID
2953 drw 10
NOTES:
1. WE must be HIGH during all address transitions.
2. During this period, I/O pins are in the output state and the input signals must not be applied.
3. OE is HIGH. If OE is LOW during a WE controlled write cycle, the write pulse width must be the greater of tWP or (tWHZ + tDW) to allow the I/O drivers to
turn off and data to be placed on the bus for the required tDW. If OE is HIGH during a WE controlled write cycle, this requirement does not apply and the
write pulse is the specified tWP.
4. Transition is measured ±200mV from steady state.
AC ELECTRICAL CHARACTERISTICS (VCC = 5.0V ± 10%, All Temperature Ranges)
6178S10(1)
6178S12
6178S15
Symbol
Parameter
Min. Max. Min. Max. Min. Max.
Clear Cycle
tCLPW(2)
CLR Pulse Width
tCLRC
CLR HIGH to WE LOW
tPOCL(3)
Power on Reset
tWECL
WE HIGH to Clear HIGH
12
15
20
5
5
5
50
60
80
5
5
5
NOTES:
1. 0°C to +70°C temperature range only.
2. Recommended duty cycle of 10% maximum.
3. This parameter guaranteed with AC load (Figure 3) by device characterization, but is not production tested.
6178S20/25
Min. Max.
25
5
100
5
Unit
ns
ns
ns
ns
2953 tbl 13
11.1
6

Share Link: 