13.3. Image Data Output
Image data is outputted from VOUT serially. Simultaneously, the STRB signal is outputted
as the timing reference for A/D conversion. The STRB is basically in synchronous with the
rising edge of CLK, and its pulse width ("H" level) is 4φ. However the pulse width ("H"
level) becomes 2φ only when DOC = 4φ. At the timing of outputting the optical black pixel
(OBP), STRB pulse is outputted only in the case BSTRB = 1. OBP timing is shown by the
hatched STRB pulse or the hatched box.
13.3.1. 2D Image : Continuous Output
* MD = 0000
1 Frame Period
32 Rows
V Blanking Period ( Differ by Accumulation Time )
OBP Row
Row 0
Row 1
H Blanking Period ( 38φ )
Row 31
OBP Row
CLK
STRB
Image Data
Data 0
DOC
Data 1
Data 30
13.3.2. Projection Image : Continuous Output
* MD = 0100
1 Frame Period
Blanking Period ( Differ by Accumulation Time )
OBP Clm Proj. 32 Data OBP Row Proj. 32 Data
Data 31
OBP Clm Proj. 32 Data
CLK
STRB
Image Data
Clm OBP Data
80φ
Clm0
DOC
Clm30 Clm31 Row OBP Data
Row0