datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

SP485EMN-L Просмотр технического описания (PDF) - Exar Corporation

Номер в каталоге
Компоненты Описание
Список матч
SP485EMN-L Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TMIN to TMAX and VCC = +5.0V +/-5% unless otherwise noted.
PARAMETERS
MIN. TYP.
SP481E
Shutdown Timing
Time to Shutdown
50
200
Driver Enable from Shutdown
40
to Output High
Driver Enable from Shutdown
40
to Output Low
Receiver Enable from
300
Shutdown to Output High
Receiver Enable from
300
Shutdown to Output Low
POWER REQUIREMENTS
Supply Voltage VCC
Supply Current
+4.75
SP481E/SP485E
No Load
900
600
SP481E
Shutdown Mode
ELECTRICAL CHARACTERISTICS
MAX. UNITS CONDITIONS
600
100
100
1000
1000
ns RE = 5V, DE = 0V
ns CL = 100pF; See Figures 4 and 6;
S2 Closed
ns CL = 100pF; See Figures 4 and 6;
S1 Closed
ns CL = 15pF; See Figures 2 and 8; S2
Closed
ns CL = 15pF; See Figures 2 and 8; S1
Closed
+5.25 Volts
µA RE, DI = 0V or VCC; DE = VCC
µA RE = 0V, DI = 0V or 5V; DE = 0V
10
µA DE = 0V, RE = VCC
ENVIRONMENTAL AND MECHANICAL
Operating Temperature
Commercial (_C_)
0
Industrial (_E_)
-40
(_M_)
-40
Storage Temperature
-65
Package
Plastic DIP (_P)
NSOIC (_N)
70
ºC
+85
ºC
+125
ºC
+150
ºC
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com

SP481E,485E_102_080810

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]