datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

RL56CSMV/6-35LP Просмотр технического описания (PDF) - Conexant Systems

Номер в каталоге
Компоненты Описание
Список матч
RL56CSMV/6-35LP
Conexant
Conexant Systems Conexant
RL56CSMV/6-35LP Datasheet PDF : 18 Pages
First Prev 11 12 13 14 15 16 17 18
5/&609
$Q\3RUWΠ0XOWL6HUYLFH $FFHVV 3URFHVVRU
Product Thermal Performance
For multi-die packages, an equivalent thermal resistance is used to represent thermal performance. This definition is used to
evaluate thermal performance of the package directly in a system level situation. The defined equivalent thermal resistance is
only valid at the stated power conditions.
Junction Temperature Calculation for Package Type: 35 mm BGA, Size = 35.0 mm * 35.0 mm * 2.27 mm
Maximum junction temperature can be calculated as:
Tj = P × θ ja + Ta
(1)
Where:
θ ja = Equivalent Package Thermal Resistance (°C/W)
T = Maximum Junction Temperature (°C)
j
T = Ambient Temperature (°C)
a
P = Package Total Power Dissipation Value (W)
For this product:
P = 1.54 (W)
θ ja = 21.30 °C/W (natural convection)
θ ja = 16.50 °C/W (1 m/s air flow)
From equation (1) and assuming maximum ambient temperature of 70 °C, maximum junction temperature for the natural
convection case is calculated as:
T
j
=
1.54
×
21.30
+
70
=
102.80
°C
Test Structure
Package thermal performance has been tested following JEDEC standards. The BGA package has been mounted at the
center of a 100 mm x 100 mm 6-layer test board and has been tested under different air flow velocities. Figure 4 shows the
system configuration.
Air Flow
LP
A
LP
B
A= 100 mm, B = 100 mm , LP= 2.27 mm and L B= 1.50 mm