IDT74FST163209
9-BIT BUS EXCHANGE SWITCH
COMMERCIAL TEMPERATURE RANGE
POWER SUPPLY CHARACTERISTICS
Symbol
ICC
ICCD
IC
Parameter
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply
Current(4)
Total Power Supply Current(6)
Test Conditions(1)
VCC = Max.
VIN = 3.4V(3)
VCC = Max.
VIN = VCC
Outputs Open
VIN = GND
Enable Pin Toggling
50% Duty Cycle
VCC = Max.
VIN = VCC
Outputs Open
VIN = GND
3 Select Pins Toggling
Min. Typ.(2) Max. Unit
— 0.5 1.5 mA
30
40 µA/
MHz/
Switch
— 2.7 3.6 mA
(9 Switches Toggling)
fi = 10MHz
50% Duty Cycle
VIN = 3.4
VIN = GND
— 3.5 5.9
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Per TTL driven input (VIN = 3.4V). All other inputs at VCC or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations.
5. Values for these conditions are examples of the ICC formula. These limits are guaranteed but not tested.
6. IC = IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ICC DHNT + ICCD (fiN)
ICC = Quiescent Current
ICC = Power Supply Current for a TTL High Input (VIN = 3.4V)
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
fi = Input Frequency
N = Number of Switches Toggling at fi
All currents are in milliamps and all frequencies are in megahertz.
3510 tbl 06
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: TA = –40°C to +85°C, VCC = 5.0V ±10%
Symbol
Description
Condition(1)
Min.(2)
Typ.
Max.
Unit
tPLH Data Propagation Delay
tPHL
A to B, B to A(3,4)
CL = 50pF
RL = 500
0.25
ns
tBX
Switch Multiplex Delay
S to A, B
1.5
6.5
ns
tPZH Switch Turn on Delay
tPZL
S to A, B
1.5
6.5
ns
tPHZ
tPLZ
|QCI|
Switch Turn off Delay
S to A, B
Charge Injection, Typical(5,7)
1.5
7
ns
1.5
pC
|QDCI| Charge Injection, Typical(6,7)
0.5
NOTES:
3510 tbl 07
1. See test circuit and waveforms.
2. Minimum limits guaranteed but not tested.
3. This parameter is guaranteed by design but not tested.
4. The bus switch contributes no propagation delay other than the RC delay of the on resistance of the switch and the load capacitance. The time constant
for the switch alone is of the order of 2.5ns for 50pF load. Since this time is constant and much smaller than the rise/fall times of typical driving signals,
it adds very little propagation delay to the system. Propagation delay on the bus switch when used in a system is determined by the driving circuit on the
driving side of the switch and its interaction with the load on the driven side.
5. Measured at switch turn off, load = 50 pF in parallel with 10 Mscope probe, VIN = 0.0 volts.
6. Measured at switch turn off through bus multiplexer, (e.g.- A1 to B1 = >A1 to B2), load = 50 pF in parallel with 10 Mscope probe, VIN at A = 0.0 volts. Charge
injection is reduced because the injection from the turn off of the A to C switch is compensated by the turn on of the B to C switch.
7. Characterized parameter. Not 100% tested.