datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

PT6301(2012) Просмотр технического описания (PDF) - Princeton Technology

Номер в каталоге
Компоненты Описание
Список матч
PT6301 Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PT6301
DATA TRANSFER METHOD AND COMMAND WRITE METHOD
Display control command and data are written by an 8-bit serial transfer.
Write timing is shown in the figure below.
Setting the CS pin to “Low” level enables a data transfer.
Data is 8 bits and is sequentially input into the DA pin from LSB (LSB first).
As shown in the figure below, data is read by the shift register at the rising edge of the shift clock, which is input into the
CP pin. If 8-bit data is input, internal load signals are automatically generated and data is written to each register and
RAM.
Therefore it is not necessary to input load signals from the outside.
Setting the CS pin to “High” disables data transfer. Data input from the point when the CS pin changes from “High” to
“Low” is recognized in 8-bit units.
tDOF F
CS
tCS H
CP
DA
B0 B1 B2 B3 B4 B5 B6 B7
B0 B1 B2 B3 B4 B5 B6 B7
B0 B1 B2 B3 B4 B5 B6 B7
LSB
M SB
1st byte
W he n data is written
to DC RAM *
Command and address data
LS B
M SB
2nd byte
Ch ar ac te r c ode d ata
LSB
M SB
3rd byte
Cha rac ter co de da ta o f th e
nex t add re ss
Note:
When data is written to RAM (DCRAM, ADRAM, CGRAM) continuously, addresses are internally incremented automatically. Therefore it is not
necessary to specify the 1st byte to write RAM data for the 2nd and later bytes.
RESET FUNCTION
Reset is executed when the RESET pin is set to “L”, (when turning power on, for example) and initializes all functions.
Initial status is as follows.
Address of each RAM.......................address “00”H
Data of each RAM.............................All contents are undefined
Display digit ......................................20 digits
Brightness adjustment ......................0/1024
All display lights ON or OFF..............OFF mode
Segment output.................................All segment outputs go “Low”
AD output..........................................All AD outputs go “Low”
Be sure to execute the reset operation when turning power on and set again according to “Setting Flowchart” after reset.
V1.2