ICS300/ICS301/ICS302
QTClock™ Quick Turn Clock Synthesizer
Electrical Specifications
Parameter
Conditions
Minimum Typical
ABSOLUTE MAXIMUM RATINGS (stresses beyond these can permanently damage the device)
Supply Voltage, VDD
Referenced to GND
Inputs
Referenced to GND
-0.5
Clock Output
Referenced to GND
-0.5
Ambient Operating Temperature
0
Soldering Temperature
Max of 10 seconds
Storage temperature
-65
DC CHARACTERISTICS (VDD = 5.0V unless otherwise noted)
Operating Voltage, VDD
3
Input High Voltage, VIH, ICLK only
ICLK (Pin 1)
(VDD/2)+1 VDD/2
Input Low Voltage, VIL, ICLK only
ICLK (Pin 1)
VDD/2
Input High Voltage, VIH
PDTS
2
Input Low Voltage, VIL
PDTS
Output High Voltage, VOH
IOH=-4mA
VDD-0.4
Output High Voltage, VOH
IOH=-25mA
2.4
Output Low Voltage, VOL
IOL=25mA
IDD Operating Supply Current, 20 MHz crystal No Load, 100MHz
20
Short Circuit Current
CLK output
±70
On-Chip Pull-up Resistor, PDTS
Pin 7
270
Input Capacitance, PDTS
Pin 7
4
AC CHARACTERISTICS (VDD = 5.0V unless otherwise noted)
Input Frequency, crystal input, ICS300 and 301
5
Input Frequency, clock input, ICS300 and 301
2
Input Frequency, clock input, ICS302
50
Output Frequency, ICS300
VDD = 4.5 to 5.5V
6
Output Frequency, ICS300
VDD = 3.0 to 3.6V
6
Output Frequency, ICS301 and ICS302
VDD = 4.5 to 5.5V
6
Output Frequency, ICS301 and ICS302
VDD = 3.0 to 3.6V
6
Output Clock Rise Time
0.8 to 2.0V
1
Output Clock Fall Time
2.0 to 0.8V
1
Output Clock Duty Cycle (Note 1)
at programmed level
45
49 to 51
Absolute Clock Period Jitter
Deviation from mean
±120
One Sigma Clock Period Jitter
50
Power-up time, PDTS goes high until Refer. out Reference on REF clk
3
Power-up time, PDTS goes high until CLK out
8
Maximum
7
VDD+0.5
VDD+0.5
70
260
150
5.5
(VDD/2)-1
0.4
0.4
27
50
125
160
100
200
200
55
10
20
Units
V
V
V
°C
°C
°C
V
V
V
V
V
V
V
V
mA
mA
k
pF
MHz
MHz
MHz
MHz
MHz
MHz
MHz
ns
ns
%
ps
ps
ms
ms
Note 1: These are typical values. The actual minimum and maximum duty cycle limits are shown on the