MOTOROLA
SEMICONDUCTOR TECHNICAL DATA
Order this document
by MPX5999D/D
0 to 1000 kPa (0 to 150 PSI)
On-Chip Signal Conditioned,
0.2 V to 4.7 V Output, Temperature
Compensated and Calibrated,
Silicon Pressure Sensor
The MPX5999D piezoresistive transducer is a state–of–the–art pressure sensor
designed for a wide range of applications, but particularly for those employing a
microcontroller or microprocessor with A/D inputs. This patented, single element
X–ducer combines advanced micromachining techniques, thin–film metallization and
bipolar semiconductor processing to provide an accurate, high level analog output signal
that is proportional to applied pressure.
Figure 1 shows a block diagram of the internal circuitry integrated on the stand–alone
sensing chip.
Features
Temperature Compensated Over 0 to 85°C
Ideally Suited for Microprocessor or Microcontroller–Based Systems
Patented Silicon Shear Stress Strain Gauge
Durable Epoxy Unibody Element
VS
3
X–ducer
SENSING
ELEMENT
THIN FILM
TEMPERATURE
COMPENSATION
AND
GAIN STAGE #1
GAIN STAGE #2
AND
GROUND
REFERENCE
SHIFT CIRCUITRY
1 Vout
2
PINS 4, 5 AND 6 ARE NO CONNECTS
GND
Figure 1. Fully Integrated Pressure Sensor Schematic
MPX5999D
X–ducer
SILICON
PRESSURE SENSORS
BASIC CHIP
CARRIER ELEMENT
CASE 867–08, STYLE 1
PIN NUMBER
1
Vout
4
N/C
2
Gnd
5
N/C
3
VS
6
N/C
NOTE: Pins 4, 5, and 6 are internal
device connections. Do not connect
to external circuitry or ground. Pin 1
is noted by the notch in the Lead.
MAXIMUM RATINGS(1)
Parametrics
Symbol
Value
Unit
Overpressure(2) (P1 > P2)
Burst Pressure(2) (P1 > P2)
Pmax
Pburst
4000
kPa
6000
kPa
Storage Temperature
Tstg
– 40° to +150
°C
Operating Temperature
TA
– 40° to +125
°C
1. TC = 25°C unless otherwise noted. Maximum Ratings apply to Case 867–08 only.
2. Extended exposure at the specified limits may cause permanent damage or degradation to the device.
3. This sensor is designed for applications where P1 is always greater than, or equal to P2.
Senseon and X–ducer are trademarks of Motorola, Inc.
(Replaces MPX5999)
©MMoottoororolal,aInSc.e1n9s97or Device Data
1

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]