OKI Semiconductor
FEDD56V62160E-01
MD56V62160E
AC Characteristics (2/2)
Parameter
Symbol
Data Input Mask Time from Write
Command
lDWD
Data Output High Impedance Time
from Precharge Command
lROH
Active Command Input Time from
Mode Register Set Command Input lMRD
(Min.)
Write Command Input Time from
Output
lOWD
MD56V62160
E-7
E-10
Min.
Max.
Min.
Max.
0
0
CL
CL
2
2
2
2
Note1, 2
Unit Note
Cycle
Cycle
Cycle
Cycle
Notes: 1. AC measurements assume that tT = 1 ns.
2. The reference level for timing of input signals is 1.4 V.
The input signal conditions are below.
VIH = 2.4 V, VIL = 0.4 V
3. Output load.
Output
Z = 50Ω
50 pF (External Load)
4. The access time is defined at 1.4 V.
5. If tT is longer than 1 ns, then the reference level for timing of input signals is VIH and VIL.