datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

MBM29BS32LF-18 Просмотр технического описания (PDF) - Spansion Inc.

Номер в каталоге
Компоненты Описание
Список матч
MBM29BS32LF-18 Datasheet PDF : 60 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MBM29BS/BT32LF-18/25
s DEVICE BUS OPERATIONS
MBM29BS/BT32LF User Bus Operations Table
Operation
Auto-Select Manufacturer
Code *2
Auto-Select Device Code *2
CE
OE
WE
WP
A0
A1
A2
A3
A4
A5
A6
A7
DQ15
to DQ0
CLK
*1
AVD
RESET
ACC
L L H X L H L L L L L L Code X
HH
L L H X H L L L L L L L Code X
HH
Extended Auto-Select
Device Code *2
L L H X L H H H L L L L Code X
L L H X H H H H L L L L Code X
HH
HH
Asynchronous Read -
Addresses Latched *3
L L H X A0 A1 A2 A3 A4 A5 A6 A7 DOUT X
HH
Asynchronous Read -
Addresses Steady State *3
L L H X A0 A1 A2 A3 A4 A5 A6 A7 DOUT X
L
H
H
Load Starting Burst Address
(CLK latch) *3
L
X
H
X A0 A1 A2 A3 A4 A5 A6 A7
X
HH
Load Starting Burst Address
(AVD latch) *3
L
X
H
X A0 A1 A2 A3 A4 A5 A6 A7
X
H/L
HH
Advance Burst to next
address *3
L L H X X X X X X X X X DOUT
HHH
Terminate Burst read
H X H X X X X X X X X X High-Z
XHH
Terminate Burst read and
start new Burst read
L X H X A0 A1 A2 A3 A4 A5 A6 A7 DOUT
HH
Terminate Burst read via
RESET
X X H X X X X X X X X X High-Z X X
L
H
Standby
H X X X X X X X X X X X High-Z X X
H
H
Output Disable
L H H X X X X X X X X X High-Z X X
H
H
Program 1 - Addresses
Latched (WE) *4
L H L X A0 A1 A2 A3 A4 A5 A6 A7 DIN
LL
H
H
Program 1 - Addresses
Latched (CLK) *4
L H L X A0 A1 A2 A3 A4 A5 A6 A7 DIN
LHH
Program 2 - Addresses
Latched (CLK) *4
L H L X A0 A1 A2 A3 A4 A5 A6 A7 DIN
HH
Program 2 - Addresses
Latched (AVD) *4
L H L X A0 A1 A2 A3 A4 A5 A6 A7 DIN H/L
HH
Boot Block Sector Write
Protection *5
X X X L XXXXXXXX X
XX
H
H
All Sector Lock
L X X X XXXXXXXX X
XX
H
L
RESET
X X X X X X X X X X X X High-Z X X
L
H
Legend: L = VIL, H = VIH, X = VIL or VIH, = Pulse input. See DC Characteristics for voltage levels.
*1: Default active edge of CLK is the rising edge.
*2: Autoselect code can be read both Asynchronous and Synchronous Read operation
*3: WE can be VIL if OE is VIL, OE at VIH initiates the write operations.
*4: For four program operations, enable to input the same program command.
*5: Protect “outermost” 2 × 8K words on low end of the boot block sectors.(SA0 and SA1)