M62211P/FP
[Mode Explained]
[I] Mode….............Activation
This is used when the FB terminal goes down to the control state potential when the DTC terminal is in up
slope. In order for the activation to occur when the DTC terminal is in down slope, the FB terminal potential
must go below the DTC terminal before the DTC terminal goes to 0.45 V.
[II] Mode…........... Output short Activation
The system is activated if the FB terminal potential goes below the DTC terminal potential before the DTC
terminal goes to 0.45 V. If there is not enough time, the output is turned OFF. (Latched)
[III] Mode….......... ON/OFF Control Activation
This mode turns off the output by forcing the DTC terminal to go down. (The system) returns as in the case
of the activation.
[IV] Mode….......... Output short (Latch)
The output is turned OFF when the FB terminal potential did not go down to the control state before the DTC
terminal went down to 0.45 V.