datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

27C512TRPDB12 Просмотр технического описания (PDF) - MAXWELL TECHNOLOGIES

Номер в каталоге
Компоненты Описание
Список матч
27C512TRPDB12
Maxwell
MAXWELL TECHNOLOGIES Maxwell
27C512TRPDB12 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
512K (64K x 8-Bit) OTP EPROM
27C512T
TABLE 8. 27C512T AC ELECTRICAL CHARACTERISTICS FOR PROGRAMMING OPERATION 1,2
(VCC = 6.0V + 0.25V, VPP = 12.5V + 0.3V, TA = 25 °C)
PARAMETER
SYMBOL
SUBGROUPS
MIN
TYP
MAX
UNIT
Address Setup Time
Address Hold Time
Data Setup Time
Data Hold Time
VPP Setup Time
VCC Setup Time
Output Enable Setup Time
Output Disable Time
CE Initial Programming Pulse Width
CE Overprogramming Pulse Width
Output Enable Hold Time
VPP Recovery Time
Data Valid from Chip Enable
tAS
9, 10, 11
2
--
--
µs
tAH
9, 10, 11
0
--
--
µs
tDS
9, 10, 11
2
--
--
µs
tDH
9, 10, 11
2
--
--
µs
tVPS
9, 10, 11
2
--
--
µs
tVCS
9, 10, 11
2
--
--
µs
tOES
9, 10, 11
2
--
--
µs
tDF3
9, 10, 11
0
--
130
ns
tPW
9, 10, 11
0.19
0.20
0.21
ms
tOPW
9, 10, 11
0.19
--
5.25
ms
tOEH
9, 10, 11
2
--
--
µs
tVR
9, 10, 11
2
--
--
µs
tDV
9, 10, 11
1
--
--
µs
1. tDF is defined as the time at which the output becomes an open circuit and data is no longer driven.
2. AC electrical parameters for programming operations are not tested. These are guaranteed by design.
3. Test Conditions:
- Input pulse levels
0.45V/2.4V
- Input rise and fall times
< 20 ns
- Referenced levels for measuring timing 0.8V/2.0V
TABLE 9. 27C512T DC ELECTRICAL CHARACTERISTICS FOR PROGRAMMING OPERATIONS1,2,3,4
(VCC = 6.0V + 0.25V, VPP = 12.5V + 0.3V, TA = 25 °C)
PARAMETER
TEST CONDITION
SYMBOL
SUBGROUPS
MIN
MAX
UNIT
Input Leakage Current
Operating VCC Current
Operating VPP Current
Input Voltage5
Output Voltage
VIN=0V to VCC
CE=PGM=VIL
IOH=-400µ A
IOH= 2.1mA
ILI
1, 2, 3
--
2
µA
ICC
1, 2, 3
--
30
mA
IPP
1, 2, 3
--
40
mA
VIH
1, 2, 3
2.2
VCC+0.56
V
VIL
1, 2, 3
-0.17
0.8
VOH
1, 2, 3
2.4
--
V
VOL
1, 2, 3
--
0.45
1. VCC must be applied before VPP and removed after VPP.
2. VPP must not exceed 13V, including overshoot.
3. Do not change VPP from VIL to 12.5V or 12.5V to VIL when CE = low.
4. DC electrical parameters for programming operations are not tested. These are guaranteed by design.
5. Device reliability may be adversely affected if the device is installed or removed while VPP = 12.5V.
06.24.03 REV 4
All data sheets are subject to change without notice 5
©2003 Maxwell Technologies
All rights reserved.

Share Link: 