datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

LY1N-CR Просмотр технического описания (PDF) - OMRON Corporation

Номер в каталоге
Компоненты Описание
Список матч
LY1N-CR
Omron
OMRON Corporation Omron
LY1N-CR Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LY
LY
Specifications
s CONTACT DATA
Load
Rated load
Contact material
Carry current
Max. operating
voltage
Max. operating
current
Max. switching
capacity
Min. permissible
load
Single contact
SPDT
Resistive load
(p.f. = 1)
15 A at 110 VAC
15 A at 24 VDC
AgCdO
15 A
250 VAC
125 VDC
15 A
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
10 A at 110 VAC
7 A at 24 VDC
Bifurcated contact
DPDT, 3PDT, 4PDT
DPDT
Resistive load
(p.f. = 1)
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
Resistive load
(p.f. = 1)
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
10 A at 110 VAC 7.5 A at 110 VAC 5 A at 110 VAC 4 A at 110 VAC
10 A at 24 VDC 5 A at 24 VDC 5 A at 24 VDC 4 A at 24 VDC
10 A
7A
10 A
7A
1,700 VA
360 W
100 mA, 5 VDC
1,100 VA
170 W
1,100 VA
240 W
830 VA
120 W
550 VA
120 W
10 mA, 5 VDC
440 VA
100 W
s COIL DATA
1- and 2-pole types – AC
Rated
voltage (V)
6
12
24
50
100/110
110/120
200/220
220/240
Rated current (mA)
50 Hz
214.10
106.50
53.80
25.70
11.70/12.90
9.90/10.80
6.20/6.80
4.80/5.30
60 Hz
183
91
46
22
10/11
8.40/9.20
5.30/5.80
4.20/4.60
Coil
resistance
()
12.20
46
180
788
3,750
4,430
12,950
18,790
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.04
0.08
0.17
0.33
0.69
1.30
3.22
5.66
14.54
24.60
19.20
32.10
54.75
94.07
83.50
136.40
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
1.00 to 1.20
(60 Hz)
Approx.
0.90 to 1.10
(60 Hz)
1- and 2-pole types – DC
Rated
voltage (V)
6
12
24
48
100/110
Rated current (mA)
150
75
36.90
18.50
9.10/10
Coil
resistance
()
40
160
650
2,600
11,000
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.16
0.33
0.73
1.37
3.20
5.72
10.60
21
45.60
86.20
Pick-up
voltage
Dropout
voltage
(% of rated voltage)
80% max. 10% min.
Maximum
voltage
110%
Power
consumption
(VA, W)
Approx.
0.90
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]