datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

LTC6102IDD-1 Просмотр технического описания (PDF) - Linear Technology

Номер в каталоге
Компоненты Описание
Список матч
LTC6102IDD-1
Linear
Linear Technology Linear
LTC6102IDD-1 Datasheet PDF : 26 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LTC6102
LTC6102-1/LTC6102HV
Electrical Characteristics (LTC6102HV) The l denotes the specifications which apply over the full
operating temperature range, otherwise specifications
V+ = 12V, V= 0V unless otherwise noted.
are
at
TA
=
25°C.
RIN
=
10Ω,
ROUT
=
10k,
VSENSE+
=
V+
(see
Figure
1
for
details),
SYMBOL PARAMETER
CONDITIONS
MIN TYP MAX UNITS
IS
Supply Current
V+ = 5V, IOUT = 0, RIN = 10k, ROUT = 100k
275
400
µA
l
475
µA
V+ = 6V, IOUT = 0, RIN = 10k, ROUT = 100k
280
425
µA
l
500
µA
V+ = 12V, IOUT = 0, RIN = 10k, ROUT = 100k
290
450
µA
l
525
µA
V+ = 100V, IOUT = 0, RIN = 10k, ROUT = 100k
420
575
µA
LTC6102HVC, LTC6102HVI
l
650
µA
LTC6102HVH
l
675
µA
fS
Sampling Frequency
10
kHz
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime. In addition to the Absolute Maximum Ratings, the
output current of the LTC6102 must be limited to ensure that the power
dissipation in the LTC6102 does not allow the die temperature to exceed
150°C. See the Applications Information “Output Current Limitations Due
to Power Dissipation” for further information.
Note 2: The LTC6102C/LTC6102C-1/LTC6102HVC are guaranteed to meet
specified performance from 0°C to 70°C. The LTC6102C/LTC6102C-1/
LTC6102HVC are designed, characterized and expected to meet specified
performance from –40°C to 85°C but are not tested or QA sampled at
these temperatures. LTC6102I/LTC6102I-1/LTC6102HVI are guaranteed
to meet specified performance from –40°C to 85°C. The LTC6102H/
LTC6102H-1/LTC6102HVH are guaranteed to meet specified performance
from –40°C to 125°C.
Note 3: These Parameters are guaranteed by design and are not 100%
tested. Thermocouple effects preclude measurements of these voltage
levels during automated testing.
Note 4: Limits are fully tested. Limit is determined by high speed
automated test capability.
Note 5: IB specification is limited by practical automated test resolution.
Please refer to the Typical Performance Characteristics section for
more information regarding actual typical performance. For tighter
specifications, please contact LTC Marketing.
6102fe
6
For more information www.linear.com/LTC6102