datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

LTC1863CGN Просмотр технического описания (PDF) - Linear Technology

Номер в каталоге
Компоненты Описание
Список матч
LTC1863CGN
Linear
Linear Technology Linear
LTC1863CGN Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LTC1863/LTC1867
TIMING CHARACTERISTICS The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C. (Note 5)
SYMBOL
fSAMPLE
tCONV
tACQ
fSCK
t1
t2
t3
t4
t5
t6
t7
t8
PARAMETER
Maximum Sampling Frequency
Conversion Time
Acquisition Time
SCK Frequency
CS/CONV High Time
SDO Valid After SCK
SDO Valid Hold Time After SCK
SDO Valid After CS/CONV
SDI Setup Time Before SCK
SDI Hold Time After SCK
SLEEP Mode Wake-Up Time
Bus Relinquish Time After CS/CONV
CONDITIONS
Short CS/CONV Pulse Mode
CL = 25pF (Note 11)
CL = 25pF
CL = 25pF
CREFCOMP = 10µF, CVREF = 2.2µF
CL = 25pF
LTC1863/LTC1867/LTC1867A
MIN
TYP
MAX
l
200
l
3
3.5
l
1.5
1.1
40
l
40
100
l
13
22
l
5
11
l
10
30
l
15
–6
l
10
4
60
l
20
40
UNITS
kHz
µs
µs
MHz
ns
ns
ns
ns
ns
ns
ms
ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime
Note 2: All voltage values are with respect to GND (unless otherwise noted).
Note 3: When these pin voltages are taken below GND or above VDD, they
will be clamped by internal diodes. This product can handle input currents
up to 100mA without latchup.
Note 4: When these pin voltages are taken below GND, they will be
clamped by internal diodes. This product can handle input currents up to
100mA below GND without latchup. These pins are not clamped to VDD.
Note 5: VDD = 5V, fSAMPLE = 200ksps at 25°C, tr = tf = 5ns and
VIN– = 2.5V for bipolar mode unless otherwise specified.
Note 6: Linearity, offset and gain error specifications apply for both
unipolar and bipolar modes. The INL and DNL are tested in bipolar mode.
Note 7: Integral nonlinearity is defined as the deviation of a code from a
straight line passing through the actual endpoints of the transfer curve.
The deviation is measured from the center of the quantization band.
Note 8: Unipolar offset is the offset voltage measured from +1/2LSB
when the output code flickers between 0000 0000 0000 0000 and
0000 0000 0000 0001 for LTC1867 and between 0000 0000 0000 and
0000 0000 0001 for LTC1863. Bipolar offset is the offset voltage measured
from –1/2LSB when output code flickers between 0000 0000 0000 0000
and 1111 1111 1111 1111 for LTC1867, and between
0000 0000 0000 and 1111 1111 1111 for LTC1863.
Note 9: Recommended operating conditions. The input range of ±2.048V
for bipolar mode is measured with respect to VIN– = 2.5V.
Note 10: Guaranteed by design, not subject to test.
Note 11: t2 of 25ns maximum allows fSCK up to 20MHz for rising capture
with 50% duty cycle and fSCK up to 40MHz for falling capture (with 3ns
setup time for the receiving logic).
For more information www.linear.com/LTC1863