Data Sheet
September 2001
L9313 Line Interface and Line Access Circuit
Full-Feature SLIC and Ringing Relay for TR-57 Applications
Operating States (continued)
Input State Coding (continued)
Table 3. Supervision Coding
Pin NSTAT
0 = off-hook or ring trip
1 = on-hook and no ring trip
Pin TRGDET
0 = ring ground
1 = no ring ground
State Definitions
Primary Control Modes
Powerup, Forward Battery
s Normal talk and battery feed state.
s Pin PT is positive with respect to pin PR.
s All ac transmission and dc feed circuits are powered
up.
s On-hook transmission is enabled.
s Thermal shutdown is active.
s Battery window comparator sense shutdown is on.
s Switch break switches (SW1 and SW2) are closed;
and ring access switches (SW3 and SW4) are open.
s VBAT1 is applied to tip and ring during on-hook condi-
tions.
s Automatic battery switch selects VBAT1 or VBAT2 dur-
ing off-hook conditions.
s All supervision circuits except for ring trip detector
are active.
s NSTAT represents the loop closure detector status.
Powerup, Reverse Battery
s Normal talk and battery feed state.
s Pin PR is positive with respect to pin PT.
s All ac transmission and dc feed circuits are powered
up.
s On-hook transmission is enabled.
s Thermal shutdown is active.
s Battery window comparator sense shutdown is on.
s Switch break switches (SW1 and SW2) are closed;
and ring access switches (SW3 and SW4) are open.
s VBAT1 is applied to tip and ring during on-hook condi-
tions.
s Automatic battery switch selects VBAT1 or VBAT2 under
off-hook conditions.
s All supervision circuits except for ring trip detector
are active.
s NSTAT represents the loop closure detector status.
Scan
s Scan clamp circuitry is active.
s Loop closure is active.
s All ac transmission, dc feed, and other supervision
circuits, including ring trip, are shut down.
s PPM and test are powered down.
s Thermal shutdown is active.
s Battery window comparator sense shutdown is on.
s On-hook transmission is disabled.
s Pin PT is positive with respect to PR and VBAT1 is
applied to tip/ring.
s Switch break switches (SW1 and SW2) are closed;
and ring access switches (SW3 and SW4) are open.
s NSTAT represents the loop closure detector status.
Agere Systems Inc.