datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

JS1-12V-FTT Просмотр технического описания (PDF) - Panasonic Corporation

Номер в каталоге
Компоненты Описание
Список матч
JS1-12V-FTT
Panasonic
Panasonic Corporation Panasonic
JS1-12V-FTT Datasheet PDF : 3 Pages
1 2 3
JS VDE
JS RELAYS MINIATURE PC BOARD TYPE
POWER RELAY
22
16
.866
.630
FEATURES
• Miniature size with universal terminal
About Cd-free contacts
footprint
16
.630
• High contact capacity: 10 A
We have introduced Cadmium free type
products to reduce Environmental
• TV-5 type available (Standard type)
Hazardous Substances.
1 Form A type TV-5
(The suffix “F” should be added to the
1 Form C type TV-5 (N.O. side only) part number)
• VDE, TÜV also approved
Please replace parts containing
mm inch • Sealed construction for automatic
Cadmium with Cadmium-free products
cleaning (Standard type)
and evaluate them with your actual
• Class B and F coil insulation type
application before use because the life of
also available.
a relay depends on the contact material
• EN60335-1 GWT compliant (Tested
and load.
by VDE) type available
• Surge voltage 6 kV type also
available
SPECIFICATIONS
Contact
Types
Standard type
Long
endurance type
Arrangement
1 Form A,
1 Form C
1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Contact material
AgSnO2 type
Nominal switching
capacity
Rating Max. switching power
(resistive
load)
Max. switching voltage
Max. switching current
10 A 250 V AC 10 A 250 V AC
10 A 125 V AC 10 A 125 V AC
6 A 277 V AC 10 A 277 V AC
2,500 VA
250 V AC, 100 V DC
10 A (AC), 5 A (DC)
Min. switching
capacity#1
100 mA, 5 V DC
Mechanical
(at 180 cpm)
107
Electrical at 10 A
125 V AC,
Expected
life (min.
ope.)
6 A 277 V AC resistive
(standard)
10 A 277 V AC resistive
(High power)
1105
2105
10 A 250 V AC resistive
(Standard: at 20 cpm)
(High power: at 20 cpm,
105C 221F)**
5 104
(No contact
only)
1.2 105
** Holding voltage should be 60% V of nominal voltage
Coil
Nominal operating power
360 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
*1 Detection current: 10mA
*2 Excluding contact bounce time
Characteristics
Max. operating speed
Types
Initial insulation resistance
Initial
breakdown
voltage*1
Between open contacts
Between contacts and
coil
Operate time*2
(at nominal voltage)
Release time (without diode)*2
(at nominal voltage)
Temperature rise (at nominal voltage)
Shock resistance
Vibration resistance
Functional*3
Destructive*4
Functional*5
Destructive
Conditions for operation,
transport and storage*6
(Not freezing and
condensing at low
temperature)
Unit weight
Ambient
temp.*7
Humidity
20 cpm
Standard
Long
type
endurance type
Min. 100 M(at 500 V DC)
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Max. 10 ms
Max. 10 ms
Max. 35C,
resistive, nominal voltage
applied to coil.
Contact carrying current:
10A, at 70C 158F
98 m/s2 {10 G}
980 m/s2 {100 G}
10 to 55 Hz at double
amplitude of 1.6 mm
10 to 55 Hz at double
amplitude of 2 mm
–40C to
+85C
–40F to
+185F
–40C to
+105C
–40F to
+221F
5 to 85% R.H.
Approx.12 g .423 oz
*3 Half-wave pulse of sine wave: 11ms; detection time: 10s
*4 Half-wave pulse of sine wave: 6ms
*5 Detection time: 10s
*6 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT
ENVIRONMENT section in Relay Technical Information.
*7 When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F
with 20C 68F as a reference) and use a coil impressed voltage that is within the
maximum allowable voltage range.
TYPICAL APPLICATIONS
1. Home appliances
Air conditioner, heater, etc.
2. Automotive
Power-window, car antenna, door-lock,
etc.
3. Office machines
PPC, facsimile, etc.
4. Vending machines
ds_61B05_en_js: 090608D
1

Share Link: 