Philips Semiconductors
ISP1521
Hi-Speed USB hub controller
The triggering voltage of the POR circuit is 2.03 V nominal. A POR is automatically
generated when VCC goes below the trigger voltage for a duration longer than 1 µs.
VCC
2.03 V
POR
≤ 683 µs
0V
At t1: clock is running and available.
Fig 3. Power-on reset timing.
t1
004aaa388
POR
EXTERNAL CLOCK
A
Stable external clock is to be available at A.
Fig 4. External clock with respect to power-on reset.
004aaa365
9397 750 13702
Product data
Rev. 03 — 24 November 2004
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
12 of 53