datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

IC80C32 Просмотр технического описания (PDF) - Integrated Circuit Solution Inc

Номер в каталоге
Компоненты Описание
Список матч
IC80C32
ICSI
Integrated Circuit Solution Inc ICSI
IC80C32 Datasheet PDF : 48 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
IC80C52
IC80C32
Using Timer 2 to Generate Baud Rates
In the IC80C52/32, setting TCLK and/or RCLK in T2CON
selects Timer 2 as the baud rate generator. Under these
conditions, the baud rates for transmit and receive can be
simultaneously different. Setting RCLK and/or TCLK puts
Timer 2 into its baud rate generator mode, as shown in
Figure 14.
The baud rate generator mode is similar to the auto-reload
mode, in that a rollover in TH2 reloads the Timer 2 registers
with the 16-bit value in the RCAP2H and RCAP2L registers,
which are preset by software.
In this case, the baud rates in Mode 1 and 3 are determined
by the Timer 2 overflow rate according to the following
equation.
Modes 1, 3 Baud Rate = Timer 2 Overflow Rate
16
Timer 2 can be configured for either timer or counter
operation. In the most typical applications, it is configured
for timer operation (C/T2 = 0). Normally, a timer increments
every machine cycle (thus, at 1/12 the oscillator frequency),
but timer operation is a different for Timer 2 when it is used
as a baud rate generator. As a baud rate generator, Timer
2 increments every state time (thus at 1/2 the oscillator
frequency). In this case, the baud rate is given by the
following formula.
Where (RCAP2H, RCAP2L) is the content of RCAP2H and
RCAP2L taken as a 16-bit unsigned integer.
Figure 13 shows Timer 2 as a baud rate generator. This
figure is valid only if RCLK + TCLK = 1 in T2CON. A rollover
in TH2 does not set TF2 and does no generate an interrupt.
Therefore, the Timer 2 interrupt does not have to be
disabled when Timer 2 is in the baud rate generator mode.
If EXEN2 is set, a 1-to-0 transition in T2EX sets EXF2 but
does not cause a reload from (RCAP2H, RCAP2L) to (TH2,
TL2). Thus, when Timer 2 is used as a baud rate generator,
T2EX can be used as an extra external interrupt.
When Timer 2 is running (TR2 = 1) as a timer in the baud
rate generator mode, programmers should not read from or
write to TH2 or TL2. Under these conditions, Timer 2 is
incremented every state time, and the results of a read or
write may not be accurate. The RCAP registers may be
read, but should not be written to, because a write might
overlap a reload and cause write and/or reload errors. Turn
Timer 2 off (clear TR2) before accessing the Timer 2 or
RCAP registers, in this case.
Modes 1, 3 =
Oscillator Frequency
Baud Rate
32x [65536 – (RCAP2H, RCAP2L)]
Table 9. Commonly Used Baud Rates Generated by Timer 1
Baud Rate
Mode 0 Max: 1 MHz
Mode 2 Max: 375K
Modes 1, 3: 62.5K
19.2K
9.6K
4.8K
2.4K
1.2K
137.5
110
110
fOSC
12 MHz
12 MHz
12 MHz
11.059 MHz
11.059 MHz
11.059 MHz
11.059 MHz
11.059 MHz
11.986 MHz
6 MHz
12 MHz
SMOD
X
1
1
1
0
0
0
0
0
0
0
Timer 1
C/T
Mode
Reload Value
X
X
X
X
X
X
0
2
FFH
0
2
FDH
0
2
FDH
0
2
FAH
0
2
F4H
0
2
E8H
0
2
1DH
0
2
72H
0
1
FEEBH
22
Integrated Circuit Solution Inc.
MC002-0B

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]