Green HLMP-355X/-356X Series
Electrical Specifications at TA = 25°C
Symbol
Description
Device
HLMP- Min. Typ. Max. Units
Test
Conditions
IV
Axial Luminous Intensity
3553
3554
3567
3568
1.6
6.7
4.2
10.6
3.2
10.0
7.0
15.0
mcd IF = 10 mA
(Figure 18)
2θ1/2
Including Angle Between Half
Luminous Intensity Points
3553
3554
3567
3568
50
Deg. Note 1 (Figure 21)
50
40
40
λPEAK Peak Wavelength
565
nm Measurement at
Peak (Figure 1)
λd
∆λ1/2
τs
C
RθJ-PIN
Dominant Wavelength
Spectral Line Halfwidth
Speed of Response
Capacitance
Thermal Resistance
569
nm Note 2
28
nm
500
ns
18
pF
VF = 0; f = 1 MHz
260
°C/W Junction to
Cathode Lead
VF
Forward Voltage
2.1 2.7
V
IF = 10 mA
(Figure 17)
VR
Reverse Breakdown Voltage
ηV
Luminous Efficacy
5.0
595
V
lm/W
IR = 100 µA
Note 3
Notes:
1. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
2. Dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color
of the device.
3. Radiant Intensity, Ie, in watts/steradian may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in candelas and
ηv is the luminous efficacy in lumens/watt.
Figure 17. Forward Current vs.
Forward Voltage.
Figure 18. Relative Luminous
Intensity vs. Forward Current.
1-106
Figure 19. Relative Efficiency
(Luminous Intensity per Unit
Current) vs. Peak Current.