HFA160MD40D
PD-2.509 rev. A 12/98
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min. Typ. Max. Units
Test Conditions
VBR
Cathode Anode Breakdown Voltage 400 V IR = 100µA
VFM
Max Forward Voltage
1.0 1.2
1.2 1.4
IF = 80A
V IF = 160A
See Fig. 1
IRM
Max Reverse Leakage Current
CT
Junction Capacitance
LS
Series Inductance
0.90 1.1
IF = 80A, TJ = 125°C
1.5 9.0 µA VR = VR Rated
See Fig. 2
2.3 12 mA TJ = 125°C, VR = 320V
280 380 pF VR = 200V
See Fig. 3
6.0 nH From top of terminal hole to mounting
plane
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min. Typ. Max. Units
Test Conditions
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
50
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
73 110 ns TJ = 25°C See
240 360
TJ = 125°C Fig. 5
IF = 80A
7.1 15
15 30
A TJ = 25°C See
TJ = 125°C Fig. 6
VR = 200V
260 700 nC TJ = 25°C See
1800 4900
TJ = 125°C Fig. 7 dif/dt = 200A/µs
300 A/µs TJ = 25°C See
260
TJ = 125°C Fig. 8
80.01 (3.150)
40.26 (1.585)
39.75 (1.565)
7.49 (0.295)
6.99 (0.275) DIA.
(2 PLCS.)
23.55 (0.927)
20.42 (0.804)
2
34.925 (1.375)
REF.
63.50 (2.500)
60.96 (2.400)
1
2
3
92.71 (3.650)
90.17 (3.550)
20.32 (0.800)
17.78 (0.700)
LEAD ASSIGNMENTS
1 - ANODE
2 - CATHODE
3 - ANODE
1/4-20 SLOTTED HEX
OUTLINE TO-244AB (ISOLATED)
Dimensions in Millimeters and (Inches)
15.75 (0.620)
14.99 (0.590)
3.35 (0.132)
3.02 (0.119)