datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

HFA16TA60CS Просмотр технического описания (PDF) - International Rectifier

Номер в каталоге
Компоненты Описание
Список матч
HFA16TA60CS
IR
International Rectifier IR
HFA16TA60CS Datasheet PDF : 6 Pages
1 2 3 4 5 6
HFA16TA60CS
Bulletin PD-20373 01/01
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min Typ Max Units
Test Conditions
VBR
Cathode Anode Breakdown Voltage 600
V IR = 100µA
1.4 1.7
IF = 8A
See Fig. 1
VFM
Max Forward Voltage
1.7 2.1 V IF = 16A
1.4 1.7
IF = 8A, TJ = 125°C
IRM
Max Reverse Leakage Current
0.3 5
µA VR = VR Rated
See Fig. 2
100 500
TJ = 125°C, VR = 0.8 x VR RatedD Rated
CT
Junction Capacitance
10 25 pF VR = 200V
See Fig. 3
LS
Series Inductance
8.0
nH
Measured lead to lead 5mm from
package body
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
Min Typ Max Units
Test Conditions
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
See Fig. 5, 6 & 16
Peak Recovery Current
See Fig. 7& 8
Reverse Recovery Charge
See Fig. 9 & 10
Peak Rate of Fall of Recovery Current
During tb
See Fig. 11 & 12
18
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
37 55 ns TJ = 25°C
55 90
TJ = 125°C
IF = 8A
3.5 5.0 A TJ = 25°C
4.5 8.0
TJ = 125°C
VR = 200V
65 138
124 360
nC
TJ = 25°C
TJ = 125°C
dif/dt = 200A/µs
240
210
A/µs
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Tlead!
RthJC
RthJA"
Wt
Parameter
Min
Lead Temperature
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Thermal Resistance, Junction to Ambient
Weight
Mounting Torque
6
5
! 0.063 in. from Case (1.6mm) for 10 sec
" Typical Socket Mount
Typ
Max Units
300
°C
3.5
1.75
K/W
80
2
g
0.07
(oz)
12
Kg-cm
10
lbf•in
2
www.irf.com