Spread-Spectrum EconOscillator
TYPICAL 2-WIRE WRITE TRANSACTION
MSB
LSB
MSB
LSB
MSB
LSB
START
1
0
1
1
A2*
A1*
A0* R/W
SLAVE
ACK
b7
b6
b5
b4 b3
b2
b1 b0
SLAVE
ACK
b7
b6
b5
b4 b3
b2
b1 b0
SLAVE
ACK
STOP
DEVICE IDENTIFIER
DEVICE READ/
COMMAND/REGISTER ADDRESS
DATA
ADDRESS WRITE
EXAMPLE 2-WIRE TRANSACTIONS (WHEN A0, A1, AND A2 ARE ZERO)
B0h
A) SINGLE BYTE WRITE
-WRITE OFFSET REGISTER
START 1 0 1 1 0 0 0 0
SLAVE
ACK
0Eh
00001110
SLAVE
ACK
DATA
OFFSET
SLAVE
ACK
STOP
B) SINGLE BYTE READ
-READ OFFSET REGISTER
B0h
0Eh
B1h
START 1 0 1 1 0 0 0 0
SLAVE
ACK
00001110
SLAVE
ACK
REPEATED
START
10110001
SLAVE
ACK
DATA
OFFSET
MASTER
NACK
STOP
C) TWO BYTE WRITE
-WRITE DAC REGISTER
B0h
08h
START
10110000
SLAVE
ACK
00001000
SLAVE
ACK
DATA
DAC MSB
SLAVE
ACK
DATA
DAC LSB
SLAVE
ACK
STOP
D) TWO BYTE READ
-READ DAC REGISTER
B0h
08h
B1h
START
10110000
SLAVE
ACK
00001000
SLAVE
ACK
REPEATED
START
10110001
SLAVE
ACK
DATA
DAC MSB
MASTER
ACK
DATA
DAC LSB
MASTER
NACK
STOP
*THE ADDRESS DETERMINED BY A0, A1, AND A2 MUST
MATCH THE ADDRESS SET IN THE ADDR REGISTER.
Figure 7. 2-Wire Transactions
Chip Information
SUBSTRATE CONNECTED TO GROUND
Package Information
For the latest package outline information and land patterns
(footprints), go to www.maxim-ic.com/packages. Note that a
“+”, “#”, or “-” in the package code indicates RoHS status only.
Package drawings may show a different suffix character, but
the drawing pertains to the package regardless of RoHS status.
PACKAGE
TYPE
8 µSOP
PACKAGE
CODE
U8-1
LAND
OUTLINE NO. PATTERN NO.
21-0036
90-0092
8 SO
S8-4
21-0041
90-0096
14 ______________________________________________________________________________________