DS1073
AC ELECTRICAL CHARACTERISTICS – CALCULATED PARAMETERS
The following characteristics are derived from various device-operating parameters (frequency, mode,
etc.). They are not specifically tested or guaranteed and may differ from the min and max limits shown by
a small amount due to internal device setup times and propagation delays. However, the equations in the
max column can be used to estimate a more accurate idea of typical device performance than the
guaranteed values.
PARAMETER
I/O ↑ from OE ↑
I/O ↓ from OE ↓
N=1
N≥2
SELX ↓ to OUT0 ↑
-Internal to External
-External to Internal
Break during SEL switch
-Internal to External
-External to Internal
PDN ↓ to I/O Hi-Z
N=1
N≥2
PDN ↓ to OUT0 Hi-Z
N=1
N≥2
PDN ↑ to I/O ↑
PDN ↑ to OUT0 ↑
I/O ↑ after Power-up
OUT0 ↑ after Power-up
SYMBOL
tEN
tDIS
tDIS
CONDITION
tSIE
tSEI
tLOW
tLOW
tPDN
tPDN
tPDN
tPDN
tSTAB
tSTAB
MIN
tM
tOUTH
0
tI/2
tI/2
tI/2
tI/2
tOUTH
0
tOUTH
0
MAX
2tM
tOUTH + tM
tOUTH
3tI/2 + tE
3tI/2 + tEhigh
tI/2 + tE
3tI/2 + tElow
tOUTH + tM
tOUTH
tOUTH + tM
tOUTH
256tM
256tM
256tM
256tM
16 of 18