P93U422
MAXIMUM RATINGS(1)
Symbol
Parameter
Value Unit
V
Power Supply Pin with – 0.5 to +7 V
CC
Respect to GND
VTERM
Terminal Voltage with
Respect to GND
(up to 7.0V)
– 0.5 to
VCC +0.5
V
T
A
Operating Temperature – 55 to +125 °C
RECOMMENDED OPERATING CONDITIONS
Grade(2)
Commercial
Military
Ambient Temp
0˚C to 70˚C
–55˚C to 125˚C
Gnd Vcc
0V 5.0V ±10%
0V 5.0V ±10%
Symbol Parameter
TBIAS
Temperature Under
Bias
TSTG
Storage Temperature
I OUT
DC Output Current
Value Unit
– 55 to +125 °C
– 65 to +150 °C
20
mA
CAPACITANCES(4)
(V
CC
=
5.0V,
T
A
=
25°C,
f
=
1.0MHz)
Symbol Parameter
Conditions Typ. Unit
CIN
COUT
Input Capacitance VIN = 0V
Output Capacitance VOUT = 0V
5 pF
7 pF
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
Symbol
Parameter
Test Conditions
VOH Output High Voltage
VCC = Min., VIN = VIH or VIL, IOH = –5.2 mA
V
OL
Output Low Voltage
VCC = Min., VIN = VIH or VIL, IOL = 8.0 mA
V Input High Level
IH
VIL Input Low Level
I
IL
Input Low Current
VIN = 0.40 V
I
Input High Current
IH
VCC = Max, VIN = 4.5V
ISC
Output Short Circuit Current (3)
V = Max., V = 0.0V
CC
OUT
ICC Power Supply Current
All Inputs = GND
VCC = Max.
T = 125˚C
A
TA = 75˚C
TA = 0˚C
TA = –55˚C
VCL Input Clamp Voltage
ICEX Output Leakage Current
IIN = –10mA
VOUT = 2.4V, VCC = Max.
VOUT = 0.5V, VCC = Max.
P93U422
Min.
Unit
Max.
2.4
V
0.45
V
2.1
V
0.8
V
–300 µA
40
µA
–70
mA
70
70
mA
80
90
–1.5
V
50
µA
–50
Notes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. For test purposes, not more than one output at a time should be shorted.
Short circuit test duration should not exceed 30 seconds.
4. This parameter is sampled and not 100% tested.