Dimensions DF-C10 (unit : mm, 1mm = 0.0394 inch)
18
10
25
55
4.2
70
Secondary terminals
Terminal 1 : Supply voltage +12...+15VDC
Terminal 2 : Supply voltage -12...-15VDC
Terminal 3 : Voltage output Vs
Terminal 4 : 0V
Mechanical characteristics
• General tolerance
± 1 mm
• Primary aperture
∅ 25 mm
• Secondary connection
Finger safe terminals
• Panel mounting
2 holes ∅ 4.2mm
(Distance between holes
38 mm x 55mm)
Remarks
• The temperature of the primary bar can not exceed 90°C.
Output Voltage / Primary Current
20VDC
16VDC
VOUT (V)
10VDC
-IPmax IPN
IPN
I Pmax
IP(A)
-10VDC
-16VDC
-20VDC
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.