Description of Mode Selection Switch (SLCK, SLTM, SLNP, PLNT, WIDE)
SLCK SLTM SLNP PLNT WIDE
MODE
H X L L L LCX005BK/BKB, NTSC, NORMAL
H X L L H LCX005BK/BKB, NTSC, WIDE
H X L H L LCX005BK/BKB, PAL, NORMAL
H X L H H LCX005BK/BKB, PAL, WIDE
H X H L L LCX024AK, NTSC, NORMAL
H X H L H LCX024AK, NTSC, WIDE
H X H H L LCX024AK, PAL, NORMAL
H X H H H LCX024AK, PAL, WIDE
L L X L L LCX009AK/AKB, NTSC, NORMAL
L L X L H LCX009AK/AKB, NTSC, WIDE
L L X H L LCX009AK/AKB, PAL, NORMAL
L L X H H LCX009AK/AKB, PAL, WIDE
L H X L L LCX027AK, NTSC, NORMAL
L H X L H LCX027AK, NTSC, WIDE
L H X H L LCX027AK, PAL, NORMAL
L H X H H LCX027AK, PAL, WIDE
∗ NORMAL (4:3 display), WIDE (16:9 display)
∗ X: Don't Care
CXD2458AR
SLFR
SLFR is the selector switch for the AC drive timing pulse (FRP). This switch selects field inversion when H and
line inversion when L. Normally, line inversion (L) is used. The transition point is one clock cycle after the
transition point of the VCK1 and VCK2 pulses.
FRP
1H inversion
(2H cycle)
1H 1H
1H 1H
1F inversion
(2F cycle)
1Field
1Field
∗ FRP polarity is not specified.
–9–