CS5181
GENERAL DESCRIPTION
The CS5181 is a monolithic CMOS 16-bit A/D
converter designed to operate in continuous mode
after being reset.
The CS5181 can operate in modulator-only mode
in which the bit stream from the modulator is the
data output from the device.
THEORY OF OPERATION
The front page of this data sheet illustrates the
block diagram of the CS5181.
Converter Initialization: Calibration and
Synchronization
The CS5181 does not have an internal power-on re-
set circuit. Therefore when power is first applied to
the device the RESET pin should be held low until
power is established. This resets the converter’s log-
ic to a known state. When power is fully established
the converter will perform a self-calibration, starting
with the first MCLK rising edge after RESET goes
high. The converter will use 988,205 MCLK cycles
to complete the calibration and to allow the digital
filter to fully settle, after which, it will output fully-
settled conversion words. The converter will then
continue to output conversion words at an output
word rate equal to MCLK/64. Figure 2 illustrates
the RESET and SYNC logic and timing for the con-
verter.
The CS5181 is designed to perform conversions
continuously with an output rate that is equivalent
to MCLK/64. The conversions are performed and
the serial port is updated independent of external
controls. The converter is designed to measure dif-
ferential bipolar input signals, and unipolar signals,
with a common mode voltage of between 1.0 V and
VREF + 0.25 V. Calibration is performed when the
RESET signal to the device is released. If RESET
is properly framed to MCLK, the converter can be
synchronized to a specific MCLK cycle at the sys-
tem level.
The SYNC signal can also be used to synchronize
multiple converters in a system. When SYNC is
used, the converter does not perform calibration.
The SYNC signal is recognized on the first rising
edge of MCLK after SYNC goes high. SYNC
aligns the output conversion to occur every 64
MCLK clock cycles after the SYNC signal is rec-
ognized and the filter is settled. After the SYNC is
initiated by going high, the converter will wait
5,161 MCLK cycles for the digital filter to settle
before putting out a fully-settled conversion word.
To synchronize multiple converters in a system, the
SYNC pulse should rise on a falling edge of the
MCLK signal. This ensures that the SYNC input to
all CS5181s in the system will be recognized on the
next rising edge of MCLK. Use of the SYNC input
RESET
CS5181
D
Q
CLK Q RESET
MCLK
RESET
FSO
MCLK
SYNC
D
Q SYNC
CLK
MCLK
988205 MCLK Cycles
SYNC
FSO
5161 MCLK Cycles
Figure 2. RESET and SYNC logic and timing.
8
DS250PP1

Share Link: 