datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

CS4373 Просмотр технического описания (PDF) - Cirrus Logic

Номер в каталоге
Компоненты Описание
Список матч
CS4373 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CS4373
2. TERMINOLOGY
Dynamic Range (Signal-to-Noise Ratio) - Ratio of the rms magnitude of the theoretical full
scale signal to the integrated rms noise from DC to 400 Hz. The following formula is used to
calculate this value:
( SNR = 20log
rms magnitude of full scale signal
rms magnitude of noise floor
Total Harmonic Distortion - Ratio of the power of the fundamental frequency to the sum of the
powers of all harmonic frequencies from DC to 400 Hz. The following formula is used to cal-
culate this value:
( THD = 10log
sum of the powers of the harmonic frequencies
power of the fundamental frequency
Full Scale Bandwidth - The bandwidth in which the converter can generate a full scale signal
while maintaining all performance specifications.
Wideband Max Amplitude - The maximum amplitude of the output signal beyond the full scale
band-width.
Differential Output Level - The peak-to-peak voltage between the analog output pins of the
converter.
Absolute Accuracy - Variation in the measured output voltage from the theoretical output volt-
age at each of the attenuation ranges. The following formula is used to calculate this value:
( absolute accuracy =
measured attenuated voltage - theoretical attenuated voltage
theoretical attenuated voltage
•100%
Relative Accuracy - Variation in the measured output voltage from the theoretical output volt-
age (relative to measured full scale signal with no attenuation) at each of the attenuation
ranges. The following formula is used to calculate this value:
( relative accuracy =
measured attenuated voltage - theoretical attenuated voltage
theoretical attenuated voltage (relative to the measured full scale voltage)
•100%
Offset Error - Variation from the theoretical common mode voltage generated by the convert-
er. The following formula is used to calculate this value:
( offset error =
measured offset
theoretical full scale voltage
•100%
Full Scale Drift - The variation of the measured full scale voltage across the specified temper-
ature range.
Offset Drift - The variation in the measured offset voltage across the specified temperature
range.
DS577F1
9

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]