IDT54/74FCT3574/3574A
3.3V CMOS OCTAL D REGISTERS (3-STATE)
MILITARY AND COMMERCIAL TEMPERATURE RANGES
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: TA = –40°C to +85°C, VCC = 2.7V to 3.6V; Military: TA = –55°C to +125°C, VCC = 2.7V to 3.6V
Symbol
VIH
Parameter
Input HIGH Level (Input pins)
Test Conditions(1)
Guaranteed Logic HIGH Level
Min. Typ.(2) Max. Unit
2.0
5.5 V
Input HIGH Level (I/O pins)
2.0
— VCC+0.5
VIL
Input LOW Level
(Input and I/O pins)
Guaranteed Logic LOW Level
–0.5
0.8 V
II H
Input HIGH Current (Input pins)(6) VCC = Max.
VI = 5.5V
±1 µA
Input HIGH Current (I/O pins)(6)
VI = VCC
±1
II L
Input LOW Current (Input pins)(6)
Input LOW Current (I/O pins)(6)
VI = GND
VI = GND
±1
±1
IOZH
High Impedance Output Current VCC = Max.
VO = VCC
±1 µA
IOZL
(3-State Output pins)(6)
VO = GND
±1
VIK
Clamp Diode Voltage
VCC = Min., IIN = –18mA
0.7 1.2 V
IODH
Output HIGH Current
VCC = 3.3V, VIN = VIH or VIL, VO = 1.5V(3)
–36 –60 –110 mA
IODL
Output LOW Current
VCC = 3.3V, VIN = VIH or VIL, VO = 1.5V(3)
50
90
200 mA
VOH
Output HIGH Voltage
VCC = Min.
IOH = –0.1mA
VCC0.2 —
—V
VIN = VIH or VIL
IOH = –3mA
2.4
3.0
VOL
Output LOW Voltage
VCC = 3.0V
VIN = VIH or VIL
VCC = Min.
IOH = –6mA MIL.
2.4(5) 3.0
IOH = –8mA COM'L.
IOL = 0.1mA
0.2 V
VIN = VIH or VIL
IOL = 16mA
0.2
0.4
IOL = 24mA
0.3 0.55
IOS
Short Circuit Current(4)
VCC = 3.0V
IOL = 24mA
VIN = VIH or VIL
VCC = Max., VO = GND(3)
0.3 0.50
–60 135 –240 mA
VH
Input Hysteresis
150
mV
ICCL
ICCH
ICCZ
Quiescent Power Supply Current
VCC = Max.,
VIN = GND or VCC
COM'L.
MIL.
0.1
10 µA
0.1
100
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at Vcc = 3.3V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. This parameter is guaranteed but not tested.
5. VOH = VCC –0.6V at rated current.
6. The test limits for this parameter is ± 5µA at TA = –55°C.