B43560, B43580
High reliability 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Leakage current Ileak
(20 °C, 5 min)
350 ... 450 V DC
1.10 VR (105 °C; VR ≤ 400 V DC, 85 °C; VR = 450 V DC)
2200 ... 15000 µF
±20% M
Self-inductance ESL
d = 51.6 mm: approx. 15 nH
d ≥ 64.3 mm: approx. 20 nH
Capacitors with low-inductance design:
d ≥ 64.3 mm: approx. 13 nH
Useful life
Requirements:
105 °C; VR; IAC,R
85 °C; VR; IAC,R
40 °C; VR; 2.0 IAC,R
Voltage endurance test
> 6000 h
> 30000 h
> 250000 h
∆C/C ≤ ±30% of initial value
ESR ≤ 3 times initial specified limit
Ileak
≤ initial specified limit
Post test requirements:
105 °C; VR; IAC.R
Vibration resistance test
2000 h
∆C/C ≤ ±10% of initial value
ESR ≤ 1.3 times initial specified limit
Ileak
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Displacement amplitude 0.75 mm, frequency range 10 ... 55 Hz,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
IEC climatic category
Detail specification
Sectional specification
To IEC 60068-1:
40/105/56 (40 °C/+105 °C/56 days damp heat test)
Similar to CECC 30301-803, CECC 30301-807
IEC 60384-4
Ripple current capability
Due to the ripple current capability of the contact elements, the following current upper limits must
not be exceeded:
Capacitor diameter
IAC,max
64.3 mm
45 A
76.9 mm
57 A
91 mm
80 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 14