datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

AZ2111-1A-5D Просмотр технического описания (PDF) - American Zettler, Inc.

Номер в каталоге
Компоненты Описание
Список матч
AZ2111-1A-5D
AZETTLER
American Zettler, Inc. AZETTLER
AZ2111-1A-5D Datasheet PDF : 3 Pages
1 2 3
AZ2110/AZ2120
RELAY ORDERING DATA
STANDARD RELAYS: UL 508: 1/8” Clearance, 1/4” Creepage
Nominal
Coil
VDC
5
6
COIL SPECIFICATIONS
Max.
Continuous
VDC
Coil
Resistance
±10%
7.3
27
8.9
40
Must
Operate
VDC
3.75
4.5
ORDER NUMBER*
Form A (SPST)
Form C (SPDT)
AZ2110–1A–5D
AZ2110–1A–6D
AZ2110–1C–5D
AZ2110–1C–6D
9
13.9
97
6.75 AZ2110–1A–9D AZ2110–1C–9D
12
17.5
155
9.0
AZ2110–1A–12D AZ2110–1C–12D
15
22.5
256
11.25 AZ2110–1A–15D AZ2110–1C–15D
18
27.4
380
13.5
AZ2110–1A–18D AZ2110–1C–18D
24
36.1
660
18.0
AZ2110–1A–24D AZ2110–1C–24D
48
68.4
2,560
36.0
AZ2110–1A–48D AZ2110–1C–48D
70
104.4
5,500
52.5
AZ2110–1A–70D AZ2110–1C–70D
110
163.2
13,450
82.5
AZ2110–1A–110D AZ2110–1C–110D
STANDARD RELAYS: 1/16” Clearance, 1/8” Creepage
COIL SPECIFICATIONS
ORDER NUMBER*
5
7.3
27
3.75 AZ2111–1A–5D AZ2111–1C–5D
6
8.9
40
4.5
AZ2111–1A–6D AZ2111–1C–6D
9
13.9
97
6.75 AZ2111–1A–9D AZ2111–1C–9D
12
17.5
155
9.0
AZ2111–1A–12D AZ2111–1C–12D
15
22.5
256
11.25 AZ2111–1A–15D AZ2111–1C–15D
18
27.4
380
13.5
AZ2111–1A–18D AZ2111–1C–18D
24
36.1
660
18.0
AZ2111–1A–24D AZ2111–1C–24D
48
68.4
2,560
36.0
AZ2111–1A–48D AZ2111–1C–48D
70
104.4
5,500
52.5
AZ2111–1A–70D AZ2111–1C–70D
110
163.2
13,450
82.5
AZ2111–1A–110D AZ2111–1C–110D
* Substitute “1B” in place of the “1A” to indicate 1 Form B contact. To indicate Class F version, add suffix “F”. For quick
connect terminals on contacts substitute “2120” or “2121” in place of “2110” or “2111”.
UL/CUR File E44211 Approved Contact Ratings
Load Type
Cycles
Volts
Form A
(NO)
Form B
(NC)
Form C
NO
NC
General Purpose
100,000 125 or 240 VAC 30 A
15 A
30 A
15 A
(Inductive)
30,000
277 VAC
30 A
30 A
30 A
30 A
Resistive
100,000 125 or 240 VAC 30 A
15 A
30 A
15 A
100,000
30 VDC
20 A
10 A
20 A
10 A
100,000
277 VAC
20 A
100,000
240 VAC
15 A
6,000
250 VAC
40 A
40 A
Ballast
6,000
277 VAC
6A
3A
6A
3A
Pilot Duty
6,000
125 VAC
800 VA
290 VA 800 VA 290 VA
30,000
125 VAC
800 VA
690 VA
100,000
125 VAC
690 VA
470 VA 275 VA
6,000
240 VAC
1152 VA 768 VA 1152 VA 768 VA
100,000
277 VAC
764 VA
764 VA
Motor Load
6,000
6,000
125 VAC
240 VAC
1 HP
3 HP
1/4 HP
1 HP
1 HP
2 HP
1/4 HP
1 HP
30,000
125 VAC
1 HP
1 HP
Definite Purpose
100,000
30,000
125 or 277 VAC
125 VAC
3/4 HP
96 LRA
30 FLA
33 LRA
10 FLA
3/4 HP
60 LRA
20 FLA
33 LRA
10 FLA
(LRA-Locked Rotor) 100,000
125 VAC
82.8 LRA
27 FLA
— 82.8 LRA —
27 FLA
(FLA-Full Load)
30,000
240 VAC
80 LRA
30 FLA
33 LRA 60 LRA 33 LRA
10 FLA 20 FLA 10 FLA
100,000
277 VAC
60 LRA
20 FLA
60 LRA
20 FLA
Tungsten
6,000
125 VAC
15 A
6,000
240 VAC
5A
6,000
120 VAC
6,000
240 VAC
15 A
3A
5A
3A
3A
3A
TV–5
25,000
120 VAC
TV–5
TV–5 TV–3
TV–3
25,000
120 VAC
TV–3
TV–3
Note: See AZ2100 Data Sheet for more complete UL and CUR approved contact ratings.
11/30/05W