datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

AT29C040A Просмотр технического описания (PDF) - Atmel Corporation

Номер в каталоге
Компоненты Описание
Список матч
AT29C040A Datasheet PDF : 17 Pages
First Prev 11 12 13 14 15 16 17
18. Software Data Protection
Enable Algorithm(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
WRITES ENABLED
LOAD DATA
TO
SECTOR (256 BYTES)(4)
ENTER DATA
PROTECT STATE(2)
AT29C040A
19. Software Data Protection
Disable Algorithm(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
Notes:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be activated at end of program
cycle.
3. Data Protect state will be deactivated at end of
program period.
4. 256 bytes of data MUST BE loaded.
LOAD DATA 20
TO
ADDRESS 5555
EXIT DATA
PROTECT STATE(3)
LOAD DATA
TO
SECTOR (256 BYTES)(4)
20. Software Protected Program Cycle Waveform(1)(2)(3)
Notes:
1. A8 through A18 must specify the sector address during each high to low transition of WE (or CE) after the software code has
been entered.
2. OE must be high when WE and CE are both low.
3. All bytes that are not loaded within the sector being programmed will be indeterminate.
11
0333L–FLASH–9/08

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]