7.3 Single-bus communication timing
User host (MCU) to send a start signal (data bus SDA line low for at least 800μ s) after AM2302 from Sleep
mode conversion to high-speed mode.The host began to signal the end of the AM2302 send a response signal
sent from the data bus SDA serial 40Bit's data, sends the byte high; data sent is followed by: Humidity high
Humidity lowTemperature highTemperature lowParity bitSend data to the end of trigger information
collection, the collection end of the sensor is automatically transferred to the sleep mode, the advent until the
next communication.
Detailed timing signal characteristics in Table 6Single-bus communication timing diagram Pic 6
Pic 6AM2302 Single-bus communication timing
Note: the temperature and humidity data read by the host from the AM2302 is always the last measured value, such as the
two measurement interval is very long, continuous read twice to the second value of real-time temperature and humidity values,
while two readtake minimum time interval be 2S.
Symbol
Tbe
Tgo
Trel
Treh
TLOW
TH0
TH1
Ten
Table 6: Single bus signal characteristics
Parameter
min typ max
Host the start signal down time 0.8
1
20
Bus master has released time
20 30 200
Response to low time
75
80
85
In response to high time
75
80
85
Signal "0", "1" low time
48
50
55
Signal "0" high time
22
26
30
Signal "1" high time
68
70
75
Sensor to release the bus time
45
50
55
Unit
mS
µS
µS
µS
µS
µS
µS
µS
NoteTo ensure the
accurate communication
of the sensor, the read
signal, in strict
accordance with the
design parameters and
timing in Table 6 and
Figure 6.
7.4 Peripherals read step example
Communication between the host and the sensor can read data through the following three steps to
complete.
Step 1
AM2302 have to wait for the power (on AM2302 power 2S crossed the unstable state, the device can not
send any instructions to read during this period), the test environment temperature and humidity data, and
record data, since the sensor into a sleep state automatically. AM2302 The SDA data line from the previous
pull-up resistor pulled up is always high, the AM2302 the SDA pin is in input state, the time detection of
external signal.
Aosong(Guangzhou) Electronics Co.,Ltd.
TEL020-36042809 / 36380552
-6-
www.aosong.com