AD707–SPECIFICATIONS (@ +25؇C and ؎15 V, unless otherwise noted)
Conditions
AD707J/A
AD707K/B
Min Typ Max Min Typ Max
Units
INPUT OFFSET VOLTAGE
Initial
vs. Temperature
Long-Term Stability
Adjustment Range
TMIN to TMAX
R2 = 20 k(Figure 19)
30 90
0.3 1.0
50 100
0.3
±4
10 25
0.1 0.3
15 45
0.3
±4
µV
µV/°C
µV
µV/month
mV
INPUT BIAS CURRENT
Average Drift
TMIN to TMAX
1.0 2.5
2.0 4.0
15 40
0.5 2.0
1.5 4.0
15 40/40/40
nA
nA
pA/°C
OFFSET CURRENT
Average Drift
VCM = 0 V
TMIN to TMAX
0.5 2.0
2.0 4.0
2 40
0.3 1.5
1.0 2.0
1 25/25/35
nA
nA
pA/°C
INPUT VOLTAGE NOISE
0.1 Hz to 10 Hz
f = 10 Hz
f = 100 Hz
f = 1 kHz
0.23 0.6
10.3 28
10.0 13.0
9.6 11.0
0.23 0.6
10.3 18
10.0 12
9.6 11.0
µV p-p
nV/Hz
nV/Hz
nV/Hz
INPUT CURRENT NOISE
0.1 Hz to 10 Hz
f = 10 Hz
f = 100 Hz
f = 1 kHz
14 35
0.32 0.9
0.14 0.27
0.12 0.18
14 30
0.32 0.8
0.14 0.23
0.12 0.17
pA p-p
pA/Hz
pA/Hz
pA/Hz
COMMON-MODE
REJECTION RATIO
OPEN-LOOP GAIN
POWER SUPPLY
REJECTION RATIO
FREQUENCY RESPONSE
Closed-Loop Bandwidth
Slew Rate
VCM = ± 13 V
TMIN to TMAX
VO = ± 10 V
RLOAD 2 k
TMIN to TMAX
VS = ± 3 V to ± 18 V
TMIN to TMAX
120 140
120 140
3 13
3 13
110 130
110 130
0.4 0.9
0.12 0.3
130 140
120 140
5 13
3 13
115 130
110 130
0.4 0.9
0.12 0.3
dB
dB
V/µV
V/µV
dB
dB
MHz
V/µs
INPUT RESISTANCE
Differential
Common Mode
24 100
45 200
M
200
300
G
OUTPUT CHARACTERISTICS
Voltage
RLOAD 10 k
13.5 14
13.5 14
±V
RLOAD 2 k
12.5 13.0
12.5 13.0
±V
RLOAD 1 k
12.0 12.5
12.0 12.5
±V
RLOAD 2 k
TMIN to TMAX
12.0 13.0
12.0 13.0
±V
OPEN-LOOP OUTPUT
RESISTANCE
60
60
POWER SUPPLY
Current, Quiescent
Power Consumption, No Load
VS = ± 15 V
VS = ± 3 V
2.5 3
75 90
7.5 9.0
2.5 3
mA
75 90
mW
7.5 9.0
mW
NOTES
All min and max specifications are guaranteed. Specifications in boldface are tested on all production units at final electrical test. Results from those tests are used to
calculate outgoing quality levels.
Specifications subject to change without notice.