AD1835
Parameter
Specifications Guaranteed
Functionality Guaranteed
Storage
TEMPERATURE RANGE
Min
Typ
25
–40
–65
Max
+85
+150
Unit
°C
°C
°C
ABSOLUTE MAXIMUM RATINGS*
(TA = 25°C, unless otherwise noted.)
AVDD, DVDD, ODVDD to AGND, DGND . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6.0 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
Digital I/O Voltage to DGND . . . . . –0.3 V to ODVDD + 0.3 V
Analog I/O Voltage to AGND . . . . . . –0.3 V to AVDD + 0.3 V
Operating Temperature Range
Industrial (A Version) . . . . . . . . . . . . . . . . . . –40°C to +85°C
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Model
AD1835AS
AD1835AS-REEL
EVAL-AD1835EB
ORDERING GUIDE
Temperature
Range
–40oC to +85oC
–40oC to +85oC
Package
Description
52-Lead MQFP
52-Lead MQFP
Evaluation Board
Package
Option
S-52
S-52
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD1835 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.