datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

CS5542-KL Просмотр технического описания (PDF) - Cirrus Logic

Номер в каталоге
Компоненты Описание
Список матч
CS5542-KL Datasheet PDF : 30 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS5542 CS5543
DATSEL[3:0]
0000
0000
0000
0000
0000
0000
0000
0000
DTEST[2:0]
000
001
010
011
100
101
110
111
FUNCTION
Normal Operation
Input Offset Voltage Cal
Noise Cal
System Offset Cal
Full-Scale Gain Cal (Uses ICAL input)
Full-Scale Gain Cal (Uses INL(INR) input)
Decimator and Modulator Power-Down
Modular Power Down
Table 1. Operation Modes
DTEST[2:0]
DATSEL[3:0]
FUNCTION
000
000
000
000
000
000
000
000
000
000
000
000
000
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
11XX
Normal Operation
Tri-State Dataout [3:0] Pins
Test Pattern #1
Test Pattern #2
Offset Cal Register Load
Offset Cal Register Load
Gain Cal Register Load
Noise Cal Register Load
Offset Cal Register Read
Offset Cal Register Read
Gain Cal Register Read
Noise Cal Register Read
Reserved
Notes: 1. MSW = Most Significant Word
2. LSW = Least Significant Word
Table 2. Control Modes
DATA TYPE
(SIGN, MSB first)
(- - -)
(MSW) (Note 1)
(LSW) (Note 2)
(MSW)
(LSW)
pins.
Offset Voltage Cal mode.
When entering calibration commands via the
DTEST lines, the calibration steps must follow a
specific sequence for the CS5542/CS5543 pair to
be properly calibrated. Figure 4 illustrates the cal-
ibration sequence for the CS5542/CS5543 chip set.
After the RST is issued, the chip set will be in the
normal mode. The first calibration step is the Input
The CS5542 is designed to digitize an input cur-
rent. This current is normally sourced from a pho-
todiode at the input of the chip. The Input Offset
Voltage Cal step is intended to remove any offset at
the front end of the modulator. This should be cal-
ibrated with no photodiode current present. If the
phototdiode is replaced with a resistor, the voltage
System
Reset
Normal
Input Offset
Voltage
Cal
Noise
Cal
System
Offset
Cal
INR(INL)
or ICAL
Gain Cal
Note: Main Current Input must be idle for all calibration modes except for Gain Cal using INL(INR).
Figure 4. Calibration Sequence CS5542/CS5543
14
Normal
DS109PP2

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]