Output Resistance
Voltage Output Protection
Voltage Range, Operating
Current
Sensitivity
Mechanical Dimensions
Weight
Temperature Range
Operating
Storage
Relative Humidity, 24 hours
ESD Sensitivity
RFI Susceptibility
Warm-up time required to meet specifications is approximately 10 minutes.
* Contact factory for OEM requirements.
1Includes the combined effects of repeatability, hysteresis, and nonlinearity.
2Nonlinearity is calculated using best-fit straight line method.
3Vz is the nominal input voltage that results in a 0 V output.
Specifications subject to change without notice.
<1Ω
Continuous Short to Ground
Power Supply
+14 V dc to +35 V dc
+25 mA, maximum
±0.0001%/% of Vs
1.663" x 2.11" x 0.563"
(42.24 mm x 53.6 mm x 14.3 mm)
60 grams
Environmental
-40°C to +85°C
-40°C to +85°C
0 to 90% @ +60°C non-condensing
IEC 801-2, Level 2
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
7B32
Rev. 0 | Page 4 of 8