Philips Semiconductors
Quad bilateral switches
Product specification
74HC4066; 74HCT4066
Resistance RON for 74HC4066 and 74HCT4066
For 74HC4066: VCC = 2.0, 4.5, 6.0 and 9.0 V; for 74HCT4066: VCC = 4.5 V; note 1; Vis is the input voltage at pins nY
or nZ, whichever is assigned as an input; see Fig.9.
SYMBOL PARAMETER
TEST CONDITIONS
MIN. TYP. MAX. UNIT
OTHER
IS (µA) VCC (V)
Tamb = 40 °C to +85 °C; note 2
RON(peak)
ON-resistance
(peak)
VI = VIH or VIL; Vis = VCC to GND 100
2.0
1000 4.5
6.0
9.0
RON(rail)
ON-resistance
(rail)
VI = VIH or VIL; Vis = GND
100
2.0
1000 4.5
6.0
9.0
VI = VIH or VIL; Vis = VCC
100
2.0
1000 4.5
6.0
9.0
RON
maximum
VI = VIH or VIL; Vis = VCC to GND
2.0
variation of
4.5
ON-resistance
between any two
6.0
channels
9.0
54 118
42 105
32 88
80
35 95
27 82
20 70
100
42 106
35 94
27 78
5
4
3
Tamb = 40 °C to +125 °C
RON(peak)
RON(rail)
ON-resistance
(peak)
ON-resistance
(rail)
VI = VIH or VIL; Vis = VCC to GND 100
2.0
1000 4.5
6.0
9.0
VI = VIH or VIL; Vis = GND
100
2.0
1000 4.5
6.0
9.0
VI = VIH or VIL; Vis = VCC
100
2.0
1000 4.5
6.0
9.0
142
126
105
115
100
85
128
113
95
Notes
1. At supply voltages approaching 2 V, the analog ON-resistance switch becomes extremely non-linear. Therefore, it is
recommended that these devices are being used to transmit digital signals only, when using these supply voltages.
2. All typical values are measured at Tamb = 25 °C.