ELECTRICAL CHARACTERISTICS
DYNAMIC ELECTRICAL CHARACTERISTICS
Table 5. Dynamic Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V VPWR 20 V, 3.0 V VDD 5.5 V, - 40 °C TA 125 °C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
PWM MODULE TIMING
Input PWM Clock Range on IN0
Input PWM Clock Low Frequency Detection Range on IN0(32)
Input PWM Clock High Frequency Detection Range on IN0(32)
fIN0
7.68
51.2
kHz
fIN0(LOW)
1.0
2.0
4.0
kHz
fIN0(HIGH)
100
200
400
kHz
Output PWM Frequency Range
fPWM
1.0
kHz
Output PWM Frequency Accuracy using Calibrated Oscillator
AFPWM(CAL)
-10
+10
%
Default Output PWM Frequency using Internal Oscillator
fPWM(0)
84
120
156
Hz
CS Calibration Low Minimum Time Detection Range
t CSB(MIN)
14
20
26
μs
CS Calibration Low Maximum Tine Detection Range
t CSB(MAX)
140
200
260
μs
Output PWM Duty-cycle Range for fpwm = 1.0 kHz for High Speed Slew
Rate(33)
RPWM_1k
6.0
94
%
Output PWM Duty-cycle Range for fpwm = 400 Hz(33)
Output PWM Duty-cycle Range for fpwm = 200 Hz (33)
RPWM_400
10
98
%
RPWM_200
5.0
98
%
INPUT TIMING
Direct Input Toggle Timeout
AUTORETRY TIMING
tIN
175
250
325
ms
Autoretry Period
tAUTO
105
150
195
ms
TEMPERATURE ON THE GND FLAG
Thermal Prewarning Detection(34)
TOTWAR
110
125
140
°C
Analog Temperature Feedback at TA = 25 °C with RCSNS=2.5 kΩ
Analog Temperature Feedback Derating with RCSNS=2.5 kΩ(35)
TFEED
DTFEED
1.15
-3.5
1.20
-3.7
1.25
V
-3.9
mV/°C
Notes
32. Clock Fail detector available for PWM_en bit is set to logic [1] and CLOCK_sel is set to logic [0].
33. The PWM ratio is measured at VHS = 50% of VPWR and for the default SR value. It is possible to put the device fully-on (PWM duty-cycle
100%) and fully-off (duty-cycle 0%). For values outside this range, a calibration is needed between the PWM duty-cycle programming
and the PWM on the output with RL = 5.0 Ω resistive load.
34. Typical value guaranteed per design.
35. Value guaranteed per statistical analysis.
10XS3412
18
Analog Integrated Circuit Device Data
Freescale Semiconductor