2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Nominal operating
power
Single side stable
1 coil latching
2 coil latching
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Mechanical
characteristics
Expected life
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Electrical
Conditions
Unit weight
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Specifications
2 Form C
Max. 75 mΩ (By voltage drop 6 V DC 1A)
AgNi type+Au clad
2 A 30 V DC, 0.5 A 125 V AC (resistive load)
60 W (DC), 62.5 VA (AC) (resistive load)
220 V DC, 125 V AC
2A
10μA 10mV DC
140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
70 mW (1.5 to 12 V DC), 100 mW (24 V DC)
140 mW (1.5 to 12 V DC), 200 mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 V (10×160μs) (FCC Part 68)
2,500 V (2×10μs) (Bellcore)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive), Min. 2×105 (1 A 30 V DC resistive),
Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
–40°C to +85°C –40°F to +185°F, Max. –40°C to +70°C (2A) Max. –40°F to +158°F (2A);
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g .071 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the