・The Diodes are made of incombustible material.However,if a Diode fails,it may emit smoke
of flame.Also,operating the Diodes near any flammable place or material may cause the
Diodes to emit smoke or flame in case the Diodes become even hotter during operation.
Design the arrangement to prevent the spread of fire.
・The Diodes should not used in an environment in the presence of acid,organic matter,or
corrosive gas(hydrogen sulfide,sulfurous acid gas.)
・The Diodes should not used in an irradiated field since they are not radiation-proof.
Insatallation
・Soldering involves temperatures which exceed the device storage temperature rating.To
avoid device damage and to ensure reliability, observe the following guidelines from the
quality assurance standard.
・Solder temperature and duration(through-hole package)
Solder
temperature
260±5℃
350±10℃
Duration
10±1second
3.0±0.5second
・The immersion depth of the lead should basically be up to the lead stopper and the distance
should be a maximum of 1.5mm from the device.
・When flow-soldering,take care to avoid immersing the package in the solder bath.
・Refer to the following torque reference When mounting the device on a heat sink. Excess
torque applied to the mounting screw causes damage to the device and weak torque will
increase the thermal resistance, both of which conditions may destory the device.
Table 1:Recommended tightening torque
Package style Screw
Recommended tightening
torque
TO-220
M3
30-50Ncm
TO-220F
TO-3P
M3
40-60Ncm
TO-3PF
TO-247
TO-3PL
M3
60-80Ncm
・The heat sink should have a flatness within±50μm and roughness within 10μm.
Also,keep the tightening torque within the limits of this specification.
・Improper handling may cause isolation breakdown leading to a critical accident.
・We recommend the use of thermal compound to optimize the efficiency of heat radiation.It is
important to evenly apply the compound and to eliminate any air viods.
Storage
・The Diodes must be stored at a standard temperature of 5 to 35℃ and relative humidity of 45
to 75%.If the storage area is very dry,a humidifier may be required.In such a case,use only
deionized water or boiled water,since the chlorine in tap water may corrode the leads.
・The Diodes should not be subjected to rapid changes in temperature to avoid condensation
on the suface of the Diodes.Therfore,store the Diodes in a place Where the temperature is
steady.
・The Diodes should not be stored on top of each other,since this may cause excessive
external force on the case.
・The Diodes should not be stored with the lead terminals remaining unprocessed.Rust may
cause presoldered connections to go fail during later processing.
・The Diodes should be stored in antistatic containers or shipping bags.